Your browser doesn't support javascript.
Minipool testing for SARS-CoV-2 RNA in US blood donors
Transfusion ; 60(SUPPL 5):276A, 2020.
Article in English | EMBASE | ID: covidwho-1041123
ABSTRACT
Background/Case Studies SARS-CoV-2 RNA has been detected by PCR in plasma, serum or whole blood specimens from hospitalized patients in studies from multiple countries. For asymptomatic individuals, several reports have described detection of SARS-CoV-2 RNA in plasma in a small number of blood donors, whereas other reports showed no detection of SARS-CoV-2 RNA in whole blood, serum or plasma from asymptomatic individuals including blood donors. No cases of transfusion-transmission of SARS-CoV-2 (or other human coronaviruses) have been reported, nor has virus been isolated from blood samples by tissue culture. We tested residual volumes of donor plasma from mini-pools (MPs) used for routine nucleic acid testing (NAT) screening to determine the frequency of SARS-CoV-2 RNAemia in blood donors in six US metropolitan regions (New York, Seattle, San Francisco, Los Angeles, Boston, Minneapolis). Study Design/

Methods:

Blood donations collected from 7 March 2020 to 30 June 2020 were tested for SARS-CoV-2 RNA. Donations were tested in plasma MPs of 6 or 16 donations (MP16 format for five regions and MP6 format for Seattle), targeting 500 MPs per region per month, using the Grifols Procleix SARS-CoV-2 transcriptionmediated amplification (TMA) assay on the Procleix Panther system. The test has a 95% limit of detection (LOD) of 16.5 copies/mL (95% CI, 12.8 to 23.6 copies/mL) by probit analysis. A confirmed positive result was defined by the detection of viral RNA upon repeat testing using the same assay and an alternate target region TMA assay (Grifols SARS-CoV-2 confirmatory TMA assay) with comparable sensitivity. Positive MPs were further tested using the Ortho VITROS anti-SARS-CoV-2 Total Ig test to detect antibodies and diluted 4-fold and tested using the Procleix SARS-CoV-2 TMA assay to determine whether the viral load was close to the 95% LOD. Results/

Findings:

A total of 8,496 MPs16 and 1,998 MPs 6, corresponding to ∼147,000 blood donations, were tested for SARS-CoV-2 RNA. One confirmed positive MP16 sample from a March donation in San Francisco was identified (0.0007% [95% CI 0.000035-0.004%]). The MP was negative for antibody and nonreactive when diluted 4-fold, suggesting a viral load below 1,000 RNA copies/mL in the individual donation.

Conclusions:

Blood donation MP-NAT indicated that SARS-CoV-2 RNAemia is rare, and when detected the RNA was at low concentration. Although future studies to determine the infectivity of RNA-positive plasma are warranted and in progress, these findings are reassuring with respect to transfusion safety and support current recommendations from WHO and regulatory agencies to not screen donors by NAT.

Full text: Available Collection: Databases of international organizations Database: EMBASE Language: English Journal: Transfusion Year: 2020 Document Type: Article

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: Databases of international organizations Database: EMBASE Language: English Journal: Transfusion Year: 2020 Document Type: Article