Your browser doesn't support javascript.
Evaluation of four commercial, fully automated SARS-CoV-2 antibody tests suggests a revision of the Siemens SARS-CoV-2 IgG assay.
Irsara, Christian; Egger, Alexander E; Prokop, Wolfgang; Nairz, Manfred; Loacker, Lorin; Sahanic, Sabina; Pizzini, Alex; Sonnweber, Thomas; Mayer, Wolfgang; Schennach, Harald; Loeffler-Ragg, Judith; Bellmann-Weiler, Rosa; Tancevski, Ivan; Weiss, Günter; Anliker, Markus; Griesmacher, Andrea; Hoermann, Gregor.
  • Irsara C; Central Institute of Clinical and Chemical Laboratory Diagnostics, University Hospital of Innsbruck, Innsbruck, Austria.
  • Egger AE; Central Institute of Clinical and Chemical Laboratory Diagnostics, University Hospital of Innsbruck, Innsbruck, Austria.
  • Prokop W; Central Institute of Clinical and Chemical Laboratory Diagnostics, University Hospital of Innsbruck, Innsbruck, Austria.
  • Nairz M; Department of Internal Medicine II, Infectious Diseases, Pneumology, Rheumatology, Medical University of Innsbruck, Innsbruck, Austria.
  • Loacker L; Central Institute of Clinical and Chemical Laboratory Diagnostics, University Hospital of Innsbruck, Innsbruck, Austria.
  • Sahanic S; Department of Internal Medicine II, Infectious Diseases, Pneumology, Rheumatology, Medical University of Innsbruck, Innsbruck, Austria.
  • Pizzini A; Department of Internal Medicine II, Infectious Diseases, Pneumology, Rheumatology, Medical University of Innsbruck, Innsbruck, Austria.
  • Sonnweber T; Department of Internal Medicine II, Infectious Diseases, Pneumology, Rheumatology, Medical University of Innsbruck, Innsbruck, Austria.
  • Mayer W; Central Institute for Blood Transfusion and Immunology (ZIB), University Hospital of Innsbruck, Innsbruck, Austria.
  • Schennach H; Central Institute for Blood Transfusion and Immunology (ZIB), University Hospital of Innsbruck, Innsbruck, Austria.
  • Loeffler-Ragg J; Department of Internal Medicine II, Infectious Diseases, Pneumology, Rheumatology, Medical University of Innsbruck, Innsbruck, Austria.
  • Bellmann-Weiler R; Department of Internal Medicine II, Infectious Diseases, Pneumology, Rheumatology, Medical University of Innsbruck, Innsbruck, Austria.
  • Tancevski I; Department of Internal Medicine II, Infectious Diseases, Pneumology, Rheumatology, Medical University of Innsbruck, Innsbruck, Austria.
  • Weiss G; Department of Internal Medicine II, Infectious Diseases, Pneumology, Rheumatology, Medical University of Innsbruck, Innsbruck, Austria.
  • Anliker M; Central Institute of Clinical and Chemical Laboratory Diagnostics, University Hospital of Innsbruck, Innsbruck, Austria.
  • Griesmacher A; Central Institute of Clinical and Chemical Laboratory Diagnostics, University Hospital of Innsbruck, Innsbruck, Austria.
  • Hoermann G; Central Institute of Clinical and Chemical Laboratory Diagnostics, University Hospital of Innsbruck, Innsbruck, Austria.
Clin Chem Lab Med ; 59(6): 1143-1154, 2021 05 26.
Article in English | MEDLINE | ID: covidwho-1067442
Preprint
This scientific journal article is probably based on a previously available preprint. It has been identified through a machine matching algorithm, human confirmation is still pending.
See preprint
ABSTRACT

OBJECTIVES:

Serological tests detect antibodies against Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) in the ongoing coronavirus disease-19 (COVID-19) pandemic. Independent external clinical validation of performance characteristics is of paramount importance.

METHODS:

Four fully automated assays, Roche Elecsys Anti-SARS-CoV-2, Abbott SARS-CoV-2 IgG, Siemens SARS-CoV-2 total (COV2T) and SARS-CoV-2 IgG (COV2G) were evaluated using 350 pre-pandemic samples and 700 samples from 245 COVID-19 patients (158 hospitalized, 87 outpatients).

RESULTS:

All tests showed very high diagnostic specificity. Sensitivities in samples collected at least 14 days after disease onset were slightly lower than manufacturers' claims for Roche (93.0%), Abbott (90.8%), and Siemens COV2T (90.3%), and distinctly lower for Siemens COV2G (78.8%). Concordantly negative results were enriched for immunocompromised patients. ROC curve analyses suggest a lowering of the cut-off index for the Siemens COV2G assay. Finally, the combination of two anti-SARS-CoV-2 antibody assays is feasible when considering borderline reactive results.

CONCLUSIONS:

Thorough on-site evaluation of commercially available serologic tests for detection of antibodies against SARS-CoV-2 remains imperative for laboratories. The potentially impaired sensitivity of the Siemens COV2G necessitates a switch to the company's newly filed SARS-CoV-2 IgG assay for follow-up studies. A combination of tests could be considered in clinical practice.
Subject(s)
Keywords

Full text: Available Collection: International databases Database: MEDLINE Main subject: Immunoglobulin G / COVID-19 Serological Testing / COVID-19 / Antibodies, Viral Type of study: Cohort study / Diagnostic study / Experimental Studies / Observational study / Prognostic study Limits: Adult / Aged / Female / Humans / Male / Middle aged / Young adult Language: English Journal: Clin Chem Lab Med Journal subject: Chemistry, Clinical / Laboratory Techniques and procedures Year: 2021 Document Type: Article Affiliation country: Cclm-2020-1758

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Main subject: Immunoglobulin G / COVID-19 Serological Testing / COVID-19 / Antibodies, Viral Type of study: Cohort study / Diagnostic study / Experimental Studies / Observational study / Prognostic study Limits: Adult / Aged / Female / Humans / Male / Middle aged / Young adult Language: English Journal: Clin Chem Lab Med Journal subject: Chemistry, Clinical / Laboratory Techniques and procedures Year: 2021 Document Type: Article Affiliation country: Cclm-2020-1758