Your browser doesn't support javascript.
Efficient Microfluidic-Based Air Sampling/Monitoring Platform for Detection of Aerosol SARS-CoV-2 On-site.
Xiong, Huiwen; Ye, Xin; Li, Yang; Qi, Jun; Fang, Xueen; Kong, Jilie.
  • Xiong H; Department of Chemistry and Institutes of Biomedical Sciences, Fudan University, Shanghai 200433, P. R. China.
  • Ye X; Department of Chemistry and Institutes of Biomedical Sciences, Fudan University, Shanghai 200433, P. R. China.
  • Li Y; Shanghai Suxin Biotechnology Co. Ltd, and IgeneTec Diagnostic Products Co. Ltd., Shanghai 201318, P. R. China.
  • Qi J; Tianjin Customs District, Tianjin 300022, P. R. China.
  • Fang X; Department of Chemistry and Institutes of Biomedical Sciences, Fudan University, Shanghai 200433, P. R. China.
  • Kong J; Department of Chemistry and Institutes of Biomedical Sciences, Fudan University, Shanghai 200433, P. R. China.
Anal Chem ; 93(9): 4270-4276, 2021 03 09.
Article in English | MEDLINE | ID: covidwho-1104412
ABSTRACT
Airborne pathogens have been considered as highly infectious and transmittable between humans. With the pandemic outbreak of the coronavirus disease 2019 (COVID-19), an on-site diagnostic system-integrated airborne pathogen-monitoring machine is recommended by experts for preventing and controlling the early stage ß-coronavirus severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spread. In this work, a small-volume rotating microfluidic fluorescence chip-integrated aerosol SARS-CoV-2 sampling system was constructed to satisfy the demand for rapid on-site sample collection and detection of SARS-CoV-2. The rotating microfluidic fluorescence system with small volume has very high sensitivity in the detection of SARS-CoV-2 (detection limit of 10 copies/µL with the shortest Ct value of 15 min), which is comparable to reverse transcription polymerase chain reaction (RT-PCR). The precision variation coefficients within/between batches are very low [coefficient of variation (CV) % ≤ 5.0%]. Our work has passed the comprehensive inspection of the microfluidic chip performance by the Shanghai Medical Device Testing Institute [National Medical Inspection (Design) no. 4408] and successfully tested 115 clinical samples. The integrated system exhibits 100% specificity, high sensitivity (10 copies/µL), and good precision (CV % ≤ 5.0%) in the rapid detection of SARS-CoV-2, thus realizing rapid monitoring and diagnostics of SARS-CoV-2 nucleic acid on-site.
Subject(s)

Full text: Available Collection: International databases Database: MEDLINE Main subject: Lab-On-A-Chip Devices / COVID-19 Testing / SARS-CoV-2 / COVID-19 Type of study: Diagnostic study / Prognostic study Limits: Humans Language: English Journal: Anal Chem Year: 2021 Document Type: Article

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Main subject: Lab-On-A-Chip Devices / COVID-19 Testing / SARS-CoV-2 / COVID-19 Type of study: Diagnostic study / Prognostic study Limits: Humans Language: English Journal: Anal Chem Year: 2021 Document Type: Article