Your browser doesn't support javascript.
Ventilated Patients With COVID-19 Show Airflow Obstruction.
Koppurapu, Vikas S; Puliaiev, Maksym; Doerschug, Kevin C; Schmidt, Gregory A.
  • Koppurapu VS; Division of Pulmonary and Critical Care Medicine, Department of Medicine, 21782University of Iowa Hospitals and Clinics, Iowa City, IA, USA.
  • Puliaiev M; Division of Pulmonary and Critical Care Medicine, Department of Medicine, 21782University of Iowa Hospitals and Clinics, Iowa City, IA, USA.
  • Doerschug KC; Division of Pulmonary and Critical Care Medicine, Department of Medicine, 21782University of Iowa Hospitals and Clinics, Iowa City, IA, USA.
  • Schmidt GA; Division of Pulmonary and Critical Care Medicine, Department of Medicine, 21782University of Iowa Hospitals and Clinics, Iowa City, IA, USA.
J Intensive Care Med ; 36(6): 696-703, 2021 Jun.
Article in English | MEDLINE | ID: covidwho-1133558
ABSTRACT

OBJECTIVE:

Many patients with coronavirus disease 2019 (COVID-19) need mechanical ventilation secondary to acute respiratory distress syndrome. Information on the respiratory system mechanical characteristics of this disease is limited. The aim of this study is to describe the respiratory system mechanical properties of ventilated COVID-19 patients. DESIGN, SETTING, AND PATIENTS Patients consecutively admitted to the medical intensive care unit at the University of Iowa Hospitals and Clinics in Iowa City, USA, from April 19 to May 1, 2020, were prospectively studied; final date of follow-up was May 1, 2020. MEASUREMENTS At the time of first patient contact, ventilator information was collected including mode, settings, peak airway pressure, plateau pressure, and total positive end expiratory pressure. Indices of airflow resistance and respiratory system compliance were calculated and analyzed. MAIN

RESULTS:

The mean age of the patients was 58 years. 6 out of 12 (50%) patients were female. Of the 21 laboratory-confirmed COVID-19 patients on invasive mechanical ventilation, 9 patients who were actively breathing on the ventilator were excluded. All the patients included were on volume-control mode. Mean [±standard deviation] ventilator indices were resistive pressure 19 [±4] cmH2O, airway resistance 20 [±4] cmH2O/L/s, and respiratory system static compliance 39 [±16] ml/cmH2O. These values are consistent with abnormally elevated resistance to airflow and reduced respiratory system compliance. Analysis of flow waveform graphics revealed a pattern consistent with airflow obstruction in all patients.

CONCLUSIONS:

Severe respiratory failure due to COVID-19 is regularly associated with airflow obstruction.
Subject(s)
Keywords

Full text: Available Collection: International databases Database: MEDLINE Main subject: Respiration, Artificial / Respiratory Distress Syndrome / Airway Obstruction / COVID-19 Type of study: Cohort study / Observational study / Prognostic study Topics: Long Covid Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: English Journal: J Intensive Care Med Journal subject: Critical Care Year: 2021 Document Type: Article Affiliation country: 08850666211000601

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Main subject: Respiration, Artificial / Respiratory Distress Syndrome / Airway Obstruction / COVID-19 Type of study: Cohort study / Observational study / Prognostic study Topics: Long Covid Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: English Journal: J Intensive Care Med Journal subject: Critical Care Year: 2021 Document Type: Article Affiliation country: 08850666211000601