Your browser doesn't support javascript.
A Numerical Analysis of the Cooling Performance of a Hybrid Personal Cooling System (HPCS): Effects of Ambient Temperature and Relative Humidity.
Xu, Pengjun; Kang, Zhanxiao; Wang, Faming.
  • Xu P; School of Design Art, Xiamen University of Technology, Xiamen 361024, China.
  • Kang Z; Thermal Environment and Ergonomics Research Group (TEERG), Institute of Textiles and Clothing, The Hong Kong Polytechnic University, Hung Hom 999007, Hong Kong.
  • Wang F; School of Architecture and Art, Central South University, Changsha 410083, China.
  • Udayraj; Department of Mechanical Engineering, Indian Institute of Technology Bhilai, Chhattisgarh 492015, India.
Int J Environ Res Public Health ; 17(14)2020 07 11.
Article in English | MEDLINE | ID: covidwho-1146935
ABSTRACT
Hybrid personal cooling systems (HPCS) incorporated with ventilation fans and phase change materials (PCMs) have shown its superior capability for mitigating workers' heat strain while performing heavy labor work in hot environments. In a previous study, the effects of thermal resistance of insulation pads, and latent heat and melting temperature of PCMs on the HPCS's thermal performance have been investigated. In addition to the aforementioned factors, environmental conditions, i.e., ambient temperature and relative humidity, also significantly affect the thermal performance of the HPCS. In this paper, a numerical parametric study was performed to investigate the effects of the environmental temperature and relative humidity (RH) on the thermal management of the HPCS. Five levels of air temperature under RH = 50% (i.e., 32, 34, 36, 38 and 40 °C) and four levels of environmental RH at two ambient temperatures of 36 and 40 °C were selected (i.e., RH = 30, 50, 70 and 90%) for the numerical analysis. Results show that high environmental temperatures could accelerate the PCM melting process and thereby weaken the cooling performance of HPCS. In the moderately hot environment (36 °C), HPCS presented good cooling performance with the maximum core temperature at around 37.5 °C during excise when the ambient RH ≤ 70%, whereas good cooling performance could be only seen under RH ≤ 50% in the extremely hot environment (40 °C). Thus, it may be concluded that the maximum environmental RH under which the HPCS exhibiting good cooling performance decreases with an increase in the environmental temperature.
Subject(s)
Keywords

Full text: Available Collection: International databases Database: MEDLINE Main subject: Temperature / Cold Temperature / Humidity Type of study: Experimental Studies Limits: Humans Language: English Year: 2020 Document Type: Article Affiliation country: Ijerph17144995

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Main subject: Temperature / Cold Temperature / Humidity Type of study: Experimental Studies Limits: Humans Language: English Year: 2020 Document Type: Article Affiliation country: Ijerph17144995