Accuracy of a Novel SARS-CoV-2 Antigen-Detecting Rapid Diagnostic Test from Standardized Self-Collected Anterior Nasal Swabs.
J Clin Med
; 10(10)2021 May 13.
Article
in English
| MEDLINE | ID: covidwho-1227038
ABSTRACT
Background Antigen-detecting rapid diagnostic tests (Ag-RDT) for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) offer new opportunities for the quick and laboratory-independent identification of infected individuals for control of the SARS-CoV-2 pandemic. Despite the potential benefits, nasopharyngeal sample collection is frequently perceived as uncomfortable by patients and requires trained healthcare personnel with protective equipment. Therefore, anterior nasal self-sampling is increasingly recognized as a valuable alternative. Methods We performed a prospective, single-center, point of care validation of an Ag-RDT using a polypropylene absorbent collector for standardized self-collected anterior nasal swabs. Real-time polymerase chain reaction (RT-PCR) from combined oropharyngeal/nasopharyngeal swabs served as a comparator. Primary endpoint was sensitivity of the standardized Ag-RDT in symptomatic patients with medium or high viral concentration (≥1 million RNA copies on RT-PCR for SARS-CoV-2). Results Between 12 February and 22 March 2021, 388 participants were enrolled. After exclusion of 9 patients for which no PCR result could be obtained, the novel Ag-RDT was evaluated based on 379 participants, of whom 273 were symptomatic and 106 asymptomatic. In 61 samples from symptomatic patients with medium or high viral load (≥1 million RNA copies), the sensitivity of the standardized Ag-RDT was 96.7% (59/61; 95% confidence interval (CI) 88.7-99.6%) for the primary endpoint. In total, 62 positive Ag-RDT results were detected out of 70 RT-PCR positive individuals, yielding an overall sensitivity of 88.6% (95% CI 78.7-94.9%). Specificity was 99.7% (95% CI 98.2-100%) in 309 RT-PCR negative individuals. Conclusions Here, we present a validation of a novel Ag-RDT with a standardized sampling process for anterior nasal self-collection, which meets World Health Organisation (WHO) criteria of ≥80% sensitivity and ≥97% specificity. Although less sensitive than RT-PCR, this assay could be beneficial due to its rapid results, ease of use, and suitability for standardized self-testing.
Full text:
Available
Collection:
International databases
Database:
MEDLINE
Type of study:
Diagnostic study
/
Experimental Studies
/
Observational study
/
Prognostic study
Language:
English
Year:
2021
Document Type:
Article
Affiliation country:
Jcm10102099
Similar
MEDLINE
...
LILACS
LIS