Your browser doesn't support javascript.
Testing of four-sample pools offers resource optimization without compromising diagnostic performance of real time reverse transcriptase-PCR assay for COVID-19.
Singh, Anirudh K; Nema, Ram Kumar; Joshi, Ankur; Shankar, Prem; Gupta, Sudheer; Yadav, Ashvini Kumar; Nema, Shashwati; Mathew, Bijina J; Shrivas, Arti; Patankar, Chitra; Raghuwanshi, Arun; Pandey, Ritu; Tripathi, Ranu; Ansari, Kudsia; Singh, Kuldeep; Yadav, Jogender; Biswas, Debasis; Singh, Sarman.
  • Singh AK; Department of Microbiology, All India Institute of Medical Sciences, Bhopal, Madhya Pradesh, India.
  • Nema RK; Regional Virology Laboratory, All India Institute of Medical Sciences, Bhopal, Madhya Pradesh, India.
  • Joshi A; Department of Community and Family Medicine, All India Institute of Medical Sciences, Bhopal, Madhya Pradesh, India.
  • Shankar P; Department of Microbiology, All India Institute of Medical Sciences, Bhopal, Madhya Pradesh, India.
  • Gupta S; Regional Virology Laboratory, All India Institute of Medical Sciences, Bhopal, Madhya Pradesh, India.
  • Yadav AK; Regional Virology Laboratory, All India Institute of Medical Sciences, Bhopal, Madhya Pradesh, India.
  • Nema S; Department of Microbiology, All India Institute of Medical Sciences, Bhopal, Madhya Pradesh, India.
  • Mathew BJ; Department of Microbiology, All India Institute of Medical Sciences, Bhopal, Madhya Pradesh, India.
  • Shrivas A; Department of Microbiology, All India Institute of Medical Sciences, Bhopal, Madhya Pradesh, India.
  • Patankar C; Department of Microbiology, All India Institute of Medical Sciences, Bhopal, Madhya Pradesh, India.
  • Raghuwanshi A; Regional Virology Laboratory, All India Institute of Medical Sciences, Bhopal, Madhya Pradesh, India.
  • Pandey R; Department of Biochemistry, All India Institute of Medical Sciences, Bhopal, Madhya Pradesh, India.
  • Tripathi R; Department of Pediatrics, All India Institute of Medical Sciences, Bhopal, Madhya Pradesh, India.
  • Ansari K; Regional Virology Laboratory, All India Institute of Medical Sciences, Bhopal, Madhya Pradesh, India.
  • Singh K; Department of Microbiology, All India Institute of Medical Sciences, Bhopal, Madhya Pradesh, India.
  • Yadav J; Department of Microbiology, All India Institute of Medical Sciences, Bhopal, Madhya Pradesh, India.
  • Biswas D; Department of Microbiology, All India Institute of Medical Sciences, Bhopal, Madhya Pradesh, India.
  • Singh S; Regional Virology Laboratory, All India Institute of Medical Sciences, Bhopal, Madhya Pradesh, India.
PLoS One ; 16(5): e0251891, 2021.
Article in English | MEDLINE | ID: covidwho-1232466
ABSTRACT
Quick identification and isolation of SARS-CoV-2 infected individuals is central to managing the COVID-19 pandemic. Real time reverse transcriptase PCR (rRT-PCR) is the gold standard for COVID-19 diagnosis. However, this resource-intensive and relatively lengthy technique is not ideally suited for mass testing. While pooled testing offers substantial savings in cost and time, the size of the optimum pool that offers complete concordance with results of individualized testing remains elusive. To determine the optimum pool size, we first evaluated the utility of pool testing using simulated 5-sample pools with varying proportions of positive and negative samples. We observed that 5-sample pool testing resulted in false negativity rate of 5% when the pools contained one positive sample. We then examined the diagnostic performance of 4-sample pools in the operational setting of a diagnostic laboratory using 500 consecutive samples in 125 pools. With background prevalence of 2.4%, this 4-sample pool testing showed 100% concordance with individualized testing and resulted in 66% and 59% reduction in resource and turnaround time, respectively. Since the negative predictive value of a diagnostic test varies inversely with prevalence, we re-tested the 4-sample pooling strategy using a fresh batch of 500 samples in 125 pools when the prevalence rose to 12.7% and recorded 100% concordance and reduction in cost and turnaround time by 36% and 30%, respectively. These observations led us to conclude that 4-sample pool testing offers the optimal blend of resource optimization and diagnostic performance across difference disease prevalence settings.
Subject(s)

Full text: Available Collection: International databases Database: MEDLINE Main subject: Specimen Handling / COVID-19 Nucleic Acid Testing / SARS-CoV-2 / COVID-19 Type of study: Diagnostic study / Experimental Studies / Observational study / Prognostic study Limits: Humans Language: English Journal: PLoS One Journal subject: Science / Medicine Year: 2021 Document Type: Article Affiliation country: Journal.pone.0251891

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Main subject: Specimen Handling / COVID-19 Nucleic Acid Testing / SARS-CoV-2 / COVID-19 Type of study: Diagnostic study / Experimental Studies / Observational study / Prognostic study Limits: Humans Language: English Journal: PLoS One Journal subject: Science / Medicine Year: 2021 Document Type: Article Affiliation country: Journal.pone.0251891