Your browser doesn't support javascript.
Uncertainty calculation methodologies in microflow measurements: Comparison of GUM, GUM-S1 and Bayesian approach.
Sousa, J A; Batista, E; Demeyer, S; Fischer, N; Pellegrino, O; Ribeiro, A S; Martins, L L.
  • Sousa JA; IPQ - Portuguese Institute for Quality, 2829-513 Caparica, Portugal.
  • Batista E; IPQ - Portuguese Institute for Quality, 2829-513 Caparica, Portugal.
  • Demeyer S; LNE - Laboratoire National de Métrologie et d'Essais, 75724 Paris, France.
  • Fischer N; LNE - Laboratoire National de Métrologie et d'Essais, 75724 Paris, France.
  • Pellegrino O; IPQ - Portuguese Institute for Quality, 2829-513 Caparica, Portugal.
  • Ribeiro AS; LNEC - National Laboratory for Civil Engineering, 1700-513 Lisboa, Portugal.
  • Martins LL; LNEC - National Laboratory for Civil Engineering, 1700-513 Lisboa, Portugal.
Measurement (Lond) ; 181: 109589, 2021 Aug.
Article in English | MEDLINE | ID: covidwho-1233535
ABSTRACT
The importance of measurement quality cannot be over emphasized in medical applications, as one is dealing with life issues and the wellbeing of society, from oncology to new-borns, and more recently to patients of the COVID-19 pandemic. In all these dire situations, the accuracy of fluid delivered according to a prescribed dose can be critical. Microflow applications are growing in importance for a wide variety of scientific fields, namely drug development and administration, Organ-on-a-Chip, or bioanalysis, but accurate and reliable measurements are a tough challenge in micro-to-femto flow operating ranges, from 2.78 × 10-4 mL/s down to 2.78 × 10-7 mL/s (1000 µL/h down to 1 µL/h). Several sources of error have been established such as the mass measurement, the fluid evaporation dependent on the gravimetric methodology implemented, the tube adsorption and the repeatability, believed to be closely related to the operating mode of the stepper motor and drive screw pitch of a syringe pump. In addition, the difficulty in dealing with microflow applications extends to the evaluation of measurement uncertainty which will qualify the quality of measurement. This is due to the conditions entailed when measuring very small values, close to zero, of a quantity such as the flow rate which is inherently positive. Alternative methods able to handle these features were developed and implemented, and their suitability will be discussed.
Keywords

Full text: Available Collection: International databases Database: MEDLINE Type of study: Experimental Studies Language: English Journal: Measurement (Lond) Year: 2021 Document Type: Article Affiliation country: J.measurement.2021.109589

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Type of study: Experimental Studies Language: English Journal: Measurement (Lond) Year: 2021 Document Type: Article Affiliation country: J.measurement.2021.109589