Your browser doesn't support javascript.
An alternative approach for bioanalytical assay optimization for wastewater-based epidemiology of SARS-CoV-2.
Boogaerts, Tim; Jacobs, Lotte; De Roeck, Naomi; Van den Bogaert, Siel; Aertgeerts, Bert; Lahousse, Lies; van Nuijs, Alexander L N; Delputte, Peter.
  • Boogaerts T; Toxicological Centre, University of Antwerp, Universiteitsplein 1, 2610 Wilrijk, Belgium. Electronic address: Tim.Boogaerts@uantwerpen.be.
  • Jacobs L; Laboratory for Microbiology, Parasitology and Hygiene, University of Antwerp, Universiteitsplein 1, 2610 Wilrijk, Belgium.
  • De Roeck N; Laboratory for Microbiology, Parasitology and Hygiene, University of Antwerp, Universiteitsplein 1, 2610 Wilrijk, Belgium.
  • Van den Bogaert S; Laboratory for Microbiology, Parasitology and Hygiene, University of Antwerp, Universiteitsplein 1, 2610 Wilrijk, Belgium.
  • Aertgeerts B; Academic Centre for General Practice, KU Leuven, Kapucijnenvoer 7, 3000 Leuven, Belgium.
  • Lahousse L; Department of Bioanalysis, Ghent University, Ottergemsesteenweg 460, 9000 Ghent, Belgium.
  • van Nuijs ALN; Toxicological Centre, University of Antwerp, Universiteitsplein 1, 2610 Wilrijk, Belgium.
  • Delputte P; Laboratory for Microbiology, Parasitology and Hygiene, University of Antwerp, Universiteitsplein 1, 2610 Wilrijk, Belgium.
Sci Total Environ ; 789: 148043, 2021 May 26.
Article in English | MEDLINE | ID: covidwho-1243225
ABSTRACT
Wastewater-based epidemiology of SARS-CoV-2 could play a role in monitoring the spread of the virus in the population and controlling possible outbreaks. However, sensitive sample preparation and detection methods are necessary to detect trace levels of SARS-CoV-2 RNA in influent wastewater (IWW). Unlike predecessors, method optimization of a SARS-CoV-2 RNA concentration and detection procedure was performed with IWW samples with high viral SARS-CoV-2 RNA loads. This is of importance since the SARS-CoV-2 genome in IWW might have already been subject to in-sewer degradation into smaller genome fragments or might be present in a different form (e.g. cell debris, …). Centricon Plus-70 (100 kDa) centrifugal filter devices resulted in the lowest and most reproducible Ct-values for SARS-CoV-2 RNA. Lowering the molecular weight cut-off did not improve our limit of detection and quantification (approximately 100 copies/µL for all genes). Quantitative polymerase chain reaction (qPCR) was employed for the amplification of the N1, N2, N3 and E-gene fragments. This is one of the first studies to apply digital polymerase chain reaction (dPCR) for the detection of SARS-CoV-2 RNA in IWW. dPCR showed high variability at low concentration levels (100 copies/µL), indicating that variability in bioanalytical methods for wastewater-based epidemiology of SARS-CoV-2 might be substantial. dPCR results in IWW were in line with the results found with qPCR. On average, the N2-gene fragment showed high in-sample stability in IWW for 10 days of storage at 4 °C. Between-sample variability was substantial due to the low native concentrations in IWW. Additionally, the E-gene fragment proved to be less stable compared to the N2-gene fragment and showed higher variability. Freezing the IWW samples resulted in a 10-fold decay of loads of the N2- and E-gene fragment in IWW.
Keywords

Full text: Available Collection: International databases Database: MEDLINE Type of study: Diagnostic study / Observational study Language: English Journal: Sci Total Environ Year: 2021 Document Type: Article

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Type of study: Diagnostic study / Observational study Language: English Journal: Sci Total Environ Year: 2021 Document Type: Article