Your browser doesn't support javascript.
The evaluation of a novel digital immunochromatographic assay with silver amplification to detect SARS-CoV-2.
Kurihara, Yoko; Kiyasu, Yoshihiko; Akashi, Yusaku; Takeuchi, Yuto; Narahara, Kenji; Mori, Sunao; Takeshige, Tomonori; Notake, Shigeyuki; Ueda, Atsuo; Nakamura, Koji; Ishikawa, Hiroichi; Suzuki, Hiromichi.
  • Kurihara Y; Division of Infectious Diseases, Department of Medicine, Tsukuba Medical Center Hospital, 1-3-1 Amakubo Tsukuba, Ibaraki, 305-8558, Japan; Department of Infectious Diseases, University of Tsukuba Hospital, 2-1-1 Amakubo, Tsukuba, Ibaraki, 305-8576, Japan.
  • Kiyasu Y; Division of Infectious Diseases, Department of Medicine, Tsukuba Medical Center Hospital, 1-3-1 Amakubo Tsukuba, Ibaraki, 305-8558, Japan; Department of Infectious Diseases, University of Tsukuba Hospital, 2-1-1 Amakubo, Tsukuba, Ibaraki, 305-8576, Japan. Electronic address: kiyasu-tuk@umin.ac.jp.
  • Akashi Y; Department of Infectious Diseases, University of Tsukuba Hospital, 2-1-1 Amakubo, Tsukuba, Ibaraki, 305-8576, Japan; Akashi Internal Medicine Clinic, 3-1-63 Asahigaoka, Kashiwara, Osaka, 582-0026, Japan.
  • Takeuchi Y; Division of Infectious Diseases, Department of Medicine, Tsukuba Medical Center Hospital, 1-3-1 Amakubo Tsukuba, Ibaraki, 305-8558, Japan; Department of Infectious Diseases, University of Tsukuba Hospital, 2-1-1 Amakubo, Tsukuba, Ibaraki, 305-8576, Japan.
  • Narahara K; Mizuho Medy Co., Ltd., 5-4 Fujinoki-machi, Tosu City, Saga, 841-0048, Japan.
  • Mori S; Mizuho Medy Co., Ltd., 5-4 Fujinoki-machi, Tosu City, Saga, 841-0048, Japan.
  • Takeshige T; Mizuho Medy Co., Ltd., 5-4 Fujinoki-machi, Tosu City, Saga, 841-0048, Japan.
  • Notake S; Department of Clinical Laboratory, Tsukuba Medical Center Hospital, 1-3-1 Amakubo, Tsukuba, Ibaraki, 305-8558, Japan.
  • Ueda A; Department of Clinical Laboratory, Tsukuba Medical Center Hospital, 1-3-1 Amakubo, Tsukuba, Ibaraki, 305-8558, Japan.
  • Nakamura K; Department of Clinical Laboratory, Tsukuba Medical Center Hospital, 1-3-1 Amakubo, Tsukuba, Ibaraki, 305-8558, Japan.
  • Ishikawa H; Department of Respiratory Medicine, Tsukuba Medical Center Hospital, 1-3-1 Amakubo, Tsukuba, Ibaraki, 305-8558, Japan.
  • Suzuki H; Department of Infectious Diseases, University of Tsukuba Hospital, 2-1-1 Amakubo, Tsukuba, Ibaraki, 305-8576, Japan; Department of Infectious Diseases, Faculty of Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki, 305-8575, Japan.
J Infect Chemother ; 27(10): 1493-1497, 2021 Oct.
Article in English | MEDLINE | ID: covidwho-1307051
Preprint
This scientific journal article is probably based on a previously available preprint. It has been identified through a machine matching algorithm, human confirmation is still pending.
See preprint
ABSTRACT

INTRODUCTION:

Rapid antigen tests are convenient for diagnosing severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2); however, they have lower sensitivities than nucleic acid amplification tests. In this study, we evaluated the diagnostic performance of Quick Chaser® Auto SARS-CoV-2, a novel digital immunochromatographic assay that is expected to have higher sensitivity than conventional antigen tests.

METHODS:

A prospective observational study was conducted between February 8 and March 24, 2021. We simultaneously obtained two nasopharyngeal samples, one for evaluation with the QuickChaser® Auto SARS-CoV-2 antigen test and the other for assessment with reverse transcription PCR (RT-PCR), considered the gold-standard reference test. The limit of detection (LOD) of the new antigen test was compared with those of four other commercially available rapid antigen tests.

RESULTS:

A total of 1401 samples were analyzed. SARS-CoV-2 was detected by reference RT-PCR in 83 (5.9%) samples, of which 36 (43.4%) were collected from symptomatic patients. The sensitivity, specificity, positive predictive value, and negative predictive value were 74.7% (95% confidence interval (CI) 64.0-83.6%), 99.8% (95% CI 99.5-100%), 96.9% (95% CI 89.2-99.6%), and 98.4% (95% CI 97.6-99.0%), respectively. When limited to samples with a cycle threshold (Ct) < 30 or those from symptomatic patients, the sensitivity increased to 98.3% and 88.9%, respectively. The QuickChaser® Auto SARS-CoV-2 detected 34-120 copies/test, which indicated greater sensitivity than the other rapid antigen tests.

CONCLUSIONS:

QuickChaser® Auto SARS-CoV-2 showed sufficient sensitivity and specificity in clinical samples of symptomatic patients. The sensitivity was comparable to RT-PCR in samples with Ct < 30.
Subject(s)
Keywords

Full text: Available Collection: International databases Database: MEDLINE Main subject: SARS-CoV-2 / COVID-19 Type of study: Diagnostic study / Experimental Studies / Observational study / Prognostic study Limits: Humans Language: English Journal: J Infect Chemother Journal subject: Microbiology / Drug Therapy Year: 2021 Document Type: Article Affiliation country: J.jiac.2021.07.006

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Main subject: SARS-CoV-2 / COVID-19 Type of study: Diagnostic study / Experimental Studies / Observational study / Prognostic study Limits: Humans Language: English Journal: J Infect Chemother Journal subject: Microbiology / Drug Therapy Year: 2021 Document Type: Article Affiliation country: J.jiac.2021.07.006