Your browser doesn't support javascript.
A rapid, ultrasensitive voltammetric biosensor for determining SARS-CoV-2 spike protein in real samples.
Liv, Lokman; Çoban, Gizem; Nakiboglu, Nuri; Kocagöz, Tanil.
  • Liv L; Electrochemistry Laboratory, Chemistry Group, The Scientific and Technological Research Council of Turkey, National Metrology Institute, (TUBITAK UME), 41470, Gebze, Kocaeli, Turkey. Electronic address: lokman.liv@tubitak.gov.tr.
  • Çoban G; Electrochemistry Laboratory, Chemistry Group, The Scientific and Technological Research Council of Turkey, National Metrology Institute, (TUBITAK UME), 41470, Gebze, Kocaeli, Turkey.
  • Nakiboglu N; Department of Chemistry, Faculty of Arts and Sciences, Balikesir University, 10145, Balikesir, Turkey.
  • Kocagöz T; Department of Medical Microbiology and Medical Biotechnology, Acibadem University, 34752, Istanbul, Turkey.
Biosens Bioelectron ; 192: 113497, 2021 Nov 15.
Article in English | MEDLINE | ID: covidwho-1309165
ABSTRACT
The ongoing coronavirus disease 2019 (COVID-19) pandemic continues to threaten public health systems all around the world. In controlling the viral outbreak, early diagnosis of COVID-19 is pivotal. This article describes a novel method of voltammetrically determining severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spike protein with a newly designed sensor involving bovine serum albumin, SARS-CoV-2 spike antibody and a functionalised graphene oxide modified glassy carbon electrode (BSA/AB/f-GO/GCE) or screen-printed electrode (BSA/AB/f-GO/SPE). The oxidation reaction based on the antibody-antigen protein interaction was evaluated as a response to SARS-CoV-2 spike protein at -200 mV and 1430 mV with the BSA/AB/f-GO/SPE and BSA/AB/f-GO/GCE, respectively. The developed sensors, BSA/AB/f-GO/SPE and BSA/AB/f-GO/GCE, could detect 1 ag/mL of virus spike protein in synthetic, saliva and oropharyngeal swab samples in 5 min and 35 min, and both sensors demonstrated a dynamic response to the SARS-CoV-2 spike protein between 1 ag/mL and 10 fg/mL. Real-time polymerase chain reaction (RT-PCR), rapid antigen test and the proposed method were applied to saliva samples. When compared to RT-PCR, it was observed that the developed method had a 92.5% specificity and 93.3% sensitivity. Moreover, BSA/AB/f-GO/SPE sensor achieved 91.7% accuracy compared to 66.7% accuracy of rapid antigen test kit in positive samples. In view of these findings, the developed sensor provides great potential for the diagnosing of COVID-19 in real samples.
Subject(s)
Keywords

Full text: Available Collection: International databases Database: MEDLINE Main subject: Biosensing Techniques / Spike Glycoprotein, Coronavirus / COVID-19 Type of study: Diagnostic study / Experimental Studies Limits: Humans Language: English Journal: Biosens Bioelectron Journal subject: Biotechnology Year: 2021 Document Type: Article

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Main subject: Biosensing Techniques / Spike Glycoprotein, Coronavirus / COVID-19 Type of study: Diagnostic study / Experimental Studies Limits: Humans Language: English Journal: Biosens Bioelectron Journal subject: Biotechnology Year: 2021 Document Type: Article