Your browser doesn't support javascript.
SARS-CoV-2 serology: Validation of high-throughput chemiluminescent immunoassay (CLIA) platforms and a field study in British Columbia.
Sekirov, Inna; Barakauskas, Vilte E; Simons, Janet; Cook, Darrel; Bates, Brandon; Burns, Laura; Masud, Shazia; Charles, Marthe; McLennan, Meghan; Mak, Annie; Chahil, Navdeep; Vijh, Rohit; Hayden, Althea; Goldfarb, David; Levett, Paul N; Krajden, Mel; Morshed, Muhammad.
  • Sekirov I; BCCDC Public Health Laboratory, BC Centre for Disease Control, Vancouver BC, Canada; Pathology and Laboratory Medicine, University of British Columbia, Vancouver BC, Canada.
  • Barakauskas VE; Pathology and Laboratory Medicine, University of British Columbia, Vancouver BC, Canada; BC Children's and Women's Hospital, Vancouver BC, Canada.
  • Simons J; BC Children's and Women's Hospital, Vancouver BC, Canada; Department of Laboratory Medicine, Providence Health Care, Vancouver BC, Canada.
  • Cook D; BCCDC Public Health Laboratory, BC Centre for Disease Control, Vancouver BC, Canada.
  • Bates B; Pathology and Laboratory Medicine, University of British Columbia, Vancouver BC, Canada; BC Children's and Women's Hospital, Vancouver BC, Canada.
  • Burns L; Pathology and Laboratory Medicine, University of British Columbia, Vancouver BC, Canada; BC Children's and Women's Hospital, Vancouver BC, Canada.
  • Masud S; Pathology and Laboratory Medicine, University of British Columbia, Vancouver BC, Canada; Surrey Memorial Hospital, Surrey BC, Canada.
  • Charles M; Pathology and Laboratory Medicine, University of British Columbia, Vancouver BC, Canada; Vancouver General Hospital, Vancouver BC, Canada.
  • McLennan M; Provincial Health Services Authority, Vancouver BC, Canada.
  • Mak A; BCCDC Public Health Laboratory, BC Centre for Disease Control, Vancouver BC, Canada.
  • Chahil N; BCCDC Public Health Laboratory, BC Centre for Disease Control, Vancouver BC, Canada.
  • Vijh R; Vancouver Coastal Health, Vancouver BC, Canada.
  • Hayden A; Vancouver Coastal Health, Vancouver BC, Canada.
  • Goldfarb D; Pathology and Laboratory Medicine, University of British Columbia, Vancouver BC, Canada; BC Children's and Women's Hospital, Vancouver BC, Canada.
  • Levett PN; BCCDC Public Health Laboratory, BC Centre for Disease Control, Vancouver BC, Canada; Pathology and Laboratory Medicine, University of British Columbia, Vancouver BC, Canada.
  • Krajden M; BCCDC Public Health Laboratory, BC Centre for Disease Control, Vancouver BC, Canada; Pathology and Laboratory Medicine, University of British Columbia, Vancouver BC, Canada.
  • Morshed M; BCCDC Public Health Laboratory, BC Centre for Disease Control, Vancouver BC, Canada; Pathology and Laboratory Medicine, University of British Columbia, Vancouver BC, Canada. Electronic address: Muhammad.Morshed@bccdc.ca.
J Clin Virol ; 142: 104914, 2021 09.
Article in English | MEDLINE | ID: covidwho-1313214
ABSTRACT

BACKGROUND:

SARS-CoV-2 antibody testing is required for estimating population seroprevalence and vaccine response studies. It may also increase case identification when used as an adjunct to routine molecular testing. We performed a validation study and evaluated the use of automated high-throughput assays in a field study of COVID-19-affected care facilities.

METHODS:

Six automated assays were assessed 1) DiaSorin LIAISONTM SARS-CoV-2 S1/S2 IgG; 2) Abbott ARCHITECTTM SARS-CoV-2 IgG; 3) Ortho VITROSTM Anti-SARS-CoV-2 Total; 4) VITROSTM Anti-SARS-CoV-2 IgG; 5) Siemens SARS-CoV-2 Total Assay; and 6) Roche ElecsysTM Anti-SARS-CoV-2. The validation study included 107 samples (42 known positive; 65 presumed negative). The field study included 296 samples (92 PCR positive; 204 PCR negative or not PCR tested). All samples were tested by the six assays.

RESULTS:

All assays had sensitivities >90% in the field study, while in the validation study, 5/6 assays were >90% sensitive and DiaSorin was 79% sensitive. Specificities and negative predictive values were >95% for all assays. Field study estimated positive predictive values at 1-10% disease prevalence were 100% for Siemens, Abbott and Roche, while DiaSorin and Ortho assays had lower PPVs at 1% prevalence, but PPVs increased at 5-10% prevalence. In the field study, addition of serology increased diagnoses by 16% compared to PCR testing alone.

CONCLUSIONS:

All assays evaluated in this study demonstrated high sensitivity and specificity for samples collected at least 14 days post-symptom onset, while sensitivity was variable 0-14 days after infection. The addition of serology to the outbreak investigations increased case detection by 16%.
Subject(s)
Keywords

Full text: Available Collection: International databases Database: MEDLINE Main subject: SARS-CoV-2 / COVID-19 Type of study: Diagnostic study / Experimental Studies / Observational study / Prognostic study Topics: Vaccines Limits: Humans Country/Region as subject: North America Language: English Journal: J Clin Virol Journal subject: Virology Year: 2021 Document Type: Article Affiliation country: J.jcv.2021.104914

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Main subject: SARS-CoV-2 / COVID-19 Type of study: Diagnostic study / Experimental Studies / Observational study / Prognostic study Topics: Vaccines Limits: Humans Country/Region as subject: North America Language: English Journal: J Clin Virol Journal subject: Virology Year: 2021 Document Type: Article Affiliation country: J.jcv.2021.104914