Your browser doesn't support javascript.
Early respiratory diagnosis: benefits of enhanced lung function assessment.
Sylvester, Karl P; Youngs, Luke; Rutter, M A; Beech, Ross; Mahadeva, Ravi.
  • Sylvester KP; Respiratory Physiology, Papworth Hospital NHS Foundation Trust, Cambridge, UK karl.sylvester@nhs.net.
  • Youngs L; Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK.
  • Rutter MA; Lung Function Department, East Sussex Healthcare NHS Trust, Saint Leonards-on-Sea, UK.
  • Beech R; Lung Function Unit, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK.
  • Mahadeva R; Lung Function Unit, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK.
BMJ Open Respir Res ; 8(1)2021 07.
Article in English | MEDLINE | ID: covidwho-1327682
ABSTRACT

INTRODUCTION:

The National Health Service for England Long Term Plan identifies respiratory disease as one of its priority workstreams. To assist with earlier and more accurate diagnosis of lung disease they recommend improvement in delivery of quality-assured spirometry. However, there is a likelihood that patients will present with abnormal gas exchange when spirometry results are normal and therefore there will be a proportion of patients whose time to diagnosis is still protracted. We wished to determine the incidence rate of this occurring within our Trust.

METHODS:

A retrospective review of all patients attending the lung function laboratory for their first pulmonary function assessment from June 2006 to December 2020 was undertaken. Forced expiratory volume in 1 s/forced vital capacity (FEV1/FVC) >-1.64 standardised residual (SR) was used to confirm no obstructive lung function abnormality and FVC >-1.64 SR to confirm no suggestion of a restrictive lung function abnormality. Lung gas transfer for carbon monoxide (TLCO) and transfer coefficient of the lung for carbon monoxide (KCO) <-1.64 SR confirmed the presence of a gas exchange abnormality. Spirometry and gas transfer reference values generated by the Global Lung Initiative were used to determine normality.

RESULTS:

Of 12 835 eligible first visits with normal FEV1/FVC and FVC, 4856 (37.8%) were identified as having an abnormally low TLCO and 3302 (25.7%) presenting with an abnormally low KCO. Of 3494 with FEV1/FVC SR <-1.64, 3316 also had a ratio of <0.70, meaning 178 (5%) of patients in this cohort would have been misclassified as having obstructive lung disease using the 0.70 cut-off recommended by the Global Initiative for Chronic Obstructive Lung Disease for diagnosing obstructive lung disease.

DISCUSSION:

In conclusion, to assist with ensuring more accurate and timely diagnosis of lung disease and enhance patients' diagnostic pathway, we recommend the performance of lung gas transfer measurements alongside spirometry in all healthcare settings. To assess and monitor gas transfer at the earliest opportunity we recommend this is implemented into new models being developed within community hubs. This will increase the identification of lung function abnormalities and provide patients with a definitive diagnosis earlier.
Subject(s)
Keywords

Full text: Available Collection: International databases Database: MEDLINE Main subject: State Medicine / Lung Type of study: Cohort study / Observational study / Prognostic study Limits: Humans Language: English Year: 2021 Document Type: Article Affiliation country: Bmjresp-2021-001012

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Main subject: State Medicine / Lung Type of study: Cohort study / Observational study / Prognostic study Limits: Humans Language: English Year: 2021 Document Type: Article Affiliation country: Bmjresp-2021-001012