Your browser doesn't support javascript.
Rapid and Sensitive SERS-Based Lateral Flow Test for SARS-CoV2-Specific IgM/IgG Antibodies.
Srivastav, Supriya; Dankov, Asen; Adanalic, Mujo; Grzeschik, Roland; Tran, Vi; Pagel-Wieder, Sibylle; Gessler, Frank; Spreitzer, Ingo; Scholz, Tatjana; Schnierle, Barbara; Anastasiou, Olympia E; Dittmer, Ulf; Schlücker, Sebastian.
  • Srivastav S; Department of Chemistry and CENIDE, University of Duisburg-Essen, 45141 Essen, Germany.
  • Dankov A; Department of Chemistry and CENIDE, University of Duisburg-Essen, 45141 Essen, Germany.
  • Adanalic M; Department of Chemistry and CENIDE, University of Duisburg-Essen, 45141 Essen, Germany.
  • Grzeschik R; Department of Chemistry and CENIDE, University of Duisburg-Essen, 45141 Essen, Germany.
  • Tran V; Department of Chemistry and CENIDE, University of Duisburg-Essen, 45141 Essen, Germany.
  • Pagel-Wieder S; Miprolab-Gesellschaft für mikrobiologische Diagnostik mbH, 37079 Göttingen, Germany.
  • Gessler F; Miprolab-Gesellschaft für mikrobiologische Diagnostik mbH, 37079 Göttingen, Germany.
  • Spreitzer I; Paul-Ehrlich Institut, Department of Microbiology, 63225 Langen, Germany.
  • Scholz T; Paul-Ehrlich Institut, Department of Virology, 63225 Langen, Germany.
  • Schnierle B; Paul-Ehrlich Institut, Department of Virology, 63225 Langen, Germany.
  • Anastasiou OE; Institute for Virology, University Clinics Essen, University of Duisburg-Essen, 45147 Essen, Germany.
  • Dittmer U; Institute for Virology, University Clinics Essen, University of Duisburg-Essen, 45147 Essen, Germany.
  • Schlücker S; Department of Chemistry and CENIDE, University of Duisburg-Essen, 45141 Essen, Germany.
Anal Chem ; 93(36): 12391-12399, 2021 09 14.
Article in English | MEDLINE | ID: covidwho-1380888
ABSTRACT
As an immune response to COVID-19 infection, patients develop SARS-CoV-2-specific IgM/IgG antibodies. Here, we compare the performance of a conventional lateral flow assay (LFA) with a surface-enhanced Raman scattering (SERS)-based LFA test for the detection of SARS-CoV-2-specific IgM/IgG in sera of COVID-19 patients. Sensitive detection of IgM might enable early serological diagnosis of acute infections. Rapid detection in serum using a custom-built SERS reader is at least an order of magnitude more sensitive than the conventional LFAs with naked-eye detection. For absolute quantification and the determination of the limit of detection (LOD), a set of reference measurements using purified (total) IgM in buffer was performed. In this purified system, the sensitivity of SERS detection is even 7 orders of magnitude higher the LOD for SERS was ca. 100 fg/mL compared to ca. 1 µg/mL for the naked-eye detection. This outlines the high potential of SERS-based LFAs in point-of-care testing once the interference of serum components with the gold conjugates and the nitrocellulose membrane is minimized.
Subject(s)

Full text: Available Collection: International databases Database: MEDLINE Main subject: RNA, Viral / COVID-19 Type of study: Diagnostic study Limits: Humans Language: English Journal: Anal Chem Year: 2021 Document Type: Article Affiliation country: Acs.analchem.1c02305

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Main subject: RNA, Viral / COVID-19 Type of study: Diagnostic study Limits: Humans Language: English Journal: Anal Chem Year: 2021 Document Type: Article Affiliation country: Acs.analchem.1c02305