Quantitative Evaluation of Aerosol Generation from Non-contact Tonometry and its Correlation with Tear Film Characteristics.
Hao, Weiting; Wu, Jianhui; Zhao, Xinheng; Liang, Danni; Yu, Xingchen; Cao, Huazheng; Wang, Yan.
  • Hao W; Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China.
  • Wu J; State Environmental Protection Key Laboratory of Urban Ambient Air Particulate Matter Pollution Prevention and Control, College of Environmental Science and Engineering, Nankai University, Tianjin, China.
  • Zhao X; Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China.
  • Liang D; Tianjin Shuangyun Environmental Protection Technology Co., Ltd, Tianjin, China.
  • Yu X; Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China.
  • Cao H; Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China.
  • Wang Y; Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China. wangyan7143@vip.sina.com.
Adv Ther ; 38(6): 3066-3076, 2021 06.
Article in English | MEDLINE | ID: covidwho-1384648
ABSTRACT

INTRODUCTION:

Ophthalmologists are inevitably exposed to tears and ocular discharge during ophthalmologic examinations and are at high risk for SARS-CoV-2 infection. To understand the role of aerosols in disease transmission, we adopted a prospective cross-sectional study design and investigated the count and size distribution of aerosols generated by a non-contact tonometer and its correlation with individual tear film characteristics.

METHODS:

This study constituted two parts. The study population included outpatients who underwent an intraocular pressure examination in an intraocular pressure examination room (Part I) and 20 participants who underwent an intraocular pressure examination in a laboratory (Part II). The following main outcomes were measured aerosol counts at 0, 50, 100, 150, and 200 cm from the non-contact tonometer (Part I); aerosol counts after each participant underwent non-contact tonometry, and lipid layer thickness score and tear film break-up time (Part II).

RESULTS:

The aerosol count decreased with increasing distance from the tonometer. The aerosol count at 0 cm had the highest value compared to that at other distances. For aerosols of diameters 0.25-0.5 µm and 0.5-1.0 µm, the count decreased at 50 cm and remained stable at further distances. For aerosols of diameters 1.0-2.5 µm and ≥ 2.5 µm, the count dropped progressively at all five distances. The aerosol count from each tonometer correlated positively with the lipid layer thickness score (r = 0.490, P = 0.028), whereas the aerosol count correlated negatively with the tear film break-up time (r = - 0.675, P = 0.001).

CONCLUSIONS:

Aerosols tended to coagulate during diffusion. A 50-cm distance from the tonometer could confer safety from aerosols with < 1.0-µm diameter. Aerosols generated during non-contact tonometry could contain a lipid layer component. Moreover, tear film stability could affect aerosol generation. Protective eyewear is recommended for reducing infection risk from aerosols. Individual tear film characteristics should be considered during non-contact tonometry.
Subject(s)
Keywords

Full text: Available Collection: International databases Database: MEDLINE Main subject: COVID-19 Type of study: Cohort study / Experimental Studies / Observational study / Prognostic study / Randomized controlled trials Limits: Humans Language: English Journal: Adv Ther Journal subject: Therapeutics Year: 2021 Document Type: Article Affiliation country: S12325-021-01740-8

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Main subject: COVID-19 Type of study: Cohort study / Experimental Studies / Observational study / Prognostic study / Randomized controlled trials Limits: Humans Language: English Journal: Adv Ther Journal subject: Therapeutics Year: 2021 Document Type: Article Affiliation country: S12325-021-01740-8