Comparative Analysis of Capillary vs Venous Blood for Serologic Detection of SARS-CoV-2 Antibodies by RPOC Lateral Flow Tests.
Open Forum Infect Dis
; 8(3): ofab043, 2021 Mar.
Article
in English
| MEDLINE | ID: covidwho-1387998
ABSTRACT
A comparison of rapid point-of-care serology tests using finger prick and venous blood was done on 278 participants. In a laboratory setting, immunoglobulin G (IgG) sensitivity neared 100%; however, IgG sensitivity dramatically dropped (82%) in field testing. Possible factors include finger prick volume variability, hemolysis, cassette readability, and operator training.