Your browser doesn't support javascript.
Development and Validation of High-Performance Liquid Chromatography Method for the Quantification of Remdesivir in Intravenous Dosage Form.
Jitta, Srinivas Reddy; Kumar, Lalit; Gangurde, Puja K; Verma, Ruchi.
  • Jitta SR; Department of Pharmaceutics, Manipal College of Pharmaceutical Sciences, Manipal Academy of Higher Education, Manipal, India.
  • Salwa; Department of Pharmaceutics, Manipal College of Pharmaceutical Sciences, Manipal Academy of Higher Education, Manipal, India.
  • Kumar L; Department of Pharmaceutics, Manipal College of Pharmaceutical Sciences, Manipal Academy of Higher Education, Manipal, India.
  • Gangurde PK; Department of Pharmaceutics, Manipal College of Pharmaceutical Sciences, Manipal Academy of Higher Education, Manipal, India.
  • Verma R; Department of Pharmaceutical Chemistry, Manipal College of Pharmaceutical Sciences, Manipal Academy of Higher Education, Manipal, India.
Assay Drug Dev Technol ; 19(8): 475-483, 2021.
Article in English | MEDLINE | ID: covidwho-1475724
ABSTRACT
Corona virus disease 2019 (COVID-19) has posed a mounting threat to public health with worldwide outbreak caused by a novel virus named severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Recently, remdesivir (RDV) has been approved by Food and Drug Administration (FDA) for treating COVID-19 patients ≥12 years old requiring hospitalization. To the best of our knowledge, a simple method to estimate RDV in the pharmaceutical formulations using high-performance liquid chromatography (HPLC) is still unexplored, highlighting the need for a precise analytical method for its quantification. The prime purpose of the current investigation was to develop and validate a well-grounded HPLC method for quantification of RDV in pharmaceutical formulations. The best chromatogram was obtained by means of an Inertsil ODS-3V column using a mobile phase of milli-Q water modified to pH 3.0 with o-phosphoric acid and acetonitrile (5050, % v/v) at a flow rate of 1.2 mL/min and wavelength of detector set at 246 nm with retention time being achieved at 6.0 min. The method was validated following International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use (ICH) Q2 (R1) guidelines for various parameters such as specificity and selectivity, system suitability, linearity, precision, accuracy, limits of detection and quantification, and robustness. The method developed for the quantification of RDV was found to be linear in the concentration range of 25-2,500 ng/mL with limit of detection and limit of quantification of 1.95 and 6.49 ng/mL, respectively. Assay value of 102% ± 1% was achieved for marketed injectable dosage form when estimated by the validated method. Therefore, in this study a simple, rapid, sensitive, selective, accurate, precise, and robust analytical method was developed and validated for the quantification of RDV using HPLC. The established method was successfully employed for quantification of RDV in marketed pharmaceutical formulation.
Subject(s)
Keywords

Full text: Available Collection: International databases Database: MEDLINE Main subject: Antiviral Agents / Adenosine Monophosphate / Alanine / Administration, Intravenous / COVID-19 Drug Treatment Type of study: Diagnostic study / Prognostic study Limits: Humans Language: English Journal: Assay Drug Dev Technol Journal subject: Pharmacology Year: 2021 Document Type: Article Affiliation country: Adt.2021.074

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Main subject: Antiviral Agents / Adenosine Monophosphate / Alanine / Administration, Intravenous / COVID-19 Drug Treatment Type of study: Diagnostic study / Prognostic study Limits: Humans Language: English Journal: Assay Drug Dev Technol Journal subject: Pharmacology Year: 2021 Document Type: Article Affiliation country: Adt.2021.074