Your browser doesn't support javascript.
Respiratory system compliance at the same PEEP level is similar in COVID and non-COVID ARDS.
Fusina, Federica; Albani, Filippo; Crisci, Serena; Morandi, Alessandro; Tansini, Francesca; Beschi, Rasula; Rosano, Antonio; Natalini, Giuseppe.
  • Fusina F; Department of Anesthesia, Intensive Care and Pain Medicine, Fondazione Poliambulanza Hospital, via Bissolati, 57, 25124, Brescia, Italy. f.fusina@gmail.com.
  • Albani F; Department of Anesthesia, Intensive Care and Pain Medicine, Fondazione Poliambulanza Hospital, via Bissolati, 57, 25124, Brescia, Italy.
  • Crisci S; Department of Anesthesia, Intensive Care and Pain Medicine, Fondazione Poliambulanza Hospital, via Bissolati, 57, 25124, Brescia, Italy.
  • Morandi A; Department of Anesthesiology and Intensive Care Medicine, Catholic University of The Sacred Heart, Rome, Italy.
  • Tansini F; Department of Anesthesia, Intensive Care and Pain Medicine, Fondazione Poliambulanza Hospital, via Bissolati, 57, 25124, Brescia, Italy.
  • Beschi R; Department of Anesthesia, Intensive Care and Pain Medicine, Fondazione Poliambulanza Hospital, via Bissolati, 57, 25124, Brescia, Italy.
  • Rosano A; Department of Anesthesia and Intensive Care, University of Insubria, Varese, Lombardia, Italy.
  • Natalini G; Department of Anesthesia, Intensive Care and Pain Medicine, Fondazione Poliambulanza Hospital, via Bissolati, 57, 25124, Brescia, Italy.
Respir Res ; 23(1): 7, 2022 Jan 12.
Article in English | MEDLINE | ID: covidwho-1622237
ABSTRACT

BACKGROUND:

The comparison of respiratory system compliance (Crs) between COVID and non-COVID ARDS patients has been the object of debate, but few studies have evaluated it when considering applied positive end expiratory pressure (PEEP), which is one of the known determinants of Crs itself. The aim of this study was to compare Crs taking into account the applied PEEP.

METHODS:

Two cohorts of patients were created those with COVID-ARDS and those with non-COVID ARDS. In the whole sample the association between Crs and type of ARDS at different PEEP levels was adjusted for anthropometric and clinical variables. As secondary analyses, patients were matched for predicted functional residual capacity and the same association was assessed. Moreover, the association between Crs and type of ARDS was reassessed at predefined PEEP level of 0, 5, 10, and 15 cmH2O with a propensity score-weighted linear model.

RESULTS:

367 patients were included in the study, 276 patients with COVID-ARDS and 91 with non-COVID ARDS. The association between Crs and type of ARDS was not significant in both the complete cohorts (p = 0.17) and in the matched cohorts (p = 0.92). This was true also for the propensity score weighted association at PEEP 5, 10 and 15 cmH2O, while it was statistically significant at PEEP 0 (with a median difference of 3 ml/cmH2O, which in our opinion is not clinically significant).

CONCLUSIONS:

The compliance of the respiratory system is similar between COVID ARDS and non-COVID ARDS when calculated at the same PEEP level and while taking into account patients' anthropometric characteristics.
Subject(s)
Keywords

Full text: Available Collection: International databases Database: MEDLINE Main subject: Respiratory Distress Syndrome / Positive-Pressure Respiration / COVID-19 Type of study: Cohort study / Diagnostic study / Experimental Studies / Observational study / Prognostic study Limits: Aged / Female / Humans / Male / Middle aged Language: English Journal: Respir Res Year: 2022 Document Type: Article Affiliation country: S12931-022-01930-0

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Main subject: Respiratory Distress Syndrome / Positive-Pressure Respiration / COVID-19 Type of study: Cohort study / Diagnostic study / Experimental Studies / Observational study / Prognostic study Limits: Aged / Female / Humans / Male / Middle aged Language: English Journal: Respir Res Year: 2022 Document Type: Article Affiliation country: S12931-022-01930-0