Your browser doesn't support javascript.
Optical design of an off-axis four-mirror objective system (OFOS) for a thermal camera
International Optical Design Conference 2021 ; 12078, 2021.
Article in English | Scopus | ID: covidwho-1642786
ABSTRACT
The optical design of a reflective objective system of a thermal camera for a syndromic surveillance system that captures bio-clinical signals, like temperature, directly related to the physical symptoms of the COVID-19 disease through thermal images is presented. The design is based on an off-axis four mirror system that allows for correcting spherical, coma, astigmatism, and field curvature aberrations. The OFOS design works on wavelengths of 7.5 µm - 14 µm, with an f-number less than 5, and a field of view (FOV) greater than 10 degrees. © COPYRIGHT SPIE. Downloading of the is permitted for personal use only.
Keywords

Full text: Available Collection: Databases of international organizations Database: Scopus Language: English Journal: International Optical Design Conference 2021 Year: 2021 Document Type: Article