Your browser doesn't support javascript.
Towards the direct detection of viral materials at the surface of protective face masks via infrared spectroscopy.
Schorer, Vanessa; Haas, Julian; Stach, Robert; Kokoric, Vjekoslav; Groß, Rüdiger; Muench, Jan; Hummel, Tim; Sobek, Harald; Mennig, Jan; Mizaikoff, Boris.
  • Schorer V; Institute of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081, Ulm, Germany.
  • Haas J; Hahn-Schickard, Sedanstraße 14, 89077, Ulm, Germany.
  • Stach R; Hahn-Schickard, Sedanstraße 14, 89077, Ulm, Germany.
  • Kokoric V; Hahn-Schickard, Sedanstraße 14, 89077, Ulm, Germany.
  • Groß R; Institute of Molecular Virology, Ulm University Medical Center, Meyerhofstr. 1, 89081, Ulm, Germany.
  • Muench J; Institute of Molecular Virology, Ulm University Medical Center, Meyerhofstr. 1, 89081, Ulm, Germany.
  • Hummel T; Labor Dr. Merk & Kollegen GmbH, Beim Braunland 1, 88416, Ochsenhausen, Germany.
  • Sobek H; Boehringer Ingelheim Therapeutics GmbH, Beim Braunland 1, 88416, Ochsenhausen, Germany.
  • Mennig J; Labor Dr. Merk & Kollegen GmbH, Beim Braunland 1, 88416, Ochsenhausen, Germany.
  • Mizaikoff B; Labor Dr. Merk & Kollegen GmbH, Beim Braunland 1, 88416, Ochsenhausen, Germany.
Sci Rep ; 12(1): 2309, 2022 02 10.
Article in English | MEDLINE | ID: covidwho-1684109
ABSTRACT
The ongoing COVID-19 pandemic represents a considerable risk for the general public and especially for health care workers. To avoid an overloading of the health care system and to control transmission chains, the development of rapid and cost-effective techniques allowing for the reliable diagnosis of individuals with acute respiratory infections are crucial. Uniquely, the present study focuses on the development of a direct face mask sampling approach, as worn (i.e., used) disposable face masks contain exogenous environmental constituents, as well as endogenously exhaled breath aerosols. Optical techniques-and specifically infrared (IR) molecular spectroscopic techniques-are promising tools for direct virus detection at the surface of such masks. In the present study, a rapid and non-destructive approach for monitoring exposure scenarios via medical face masks using attenuated total reflection infrared spectroscopy is presented. Complementarily, IR external reflection spectroscopy was evaluated in comparison for rapid mask analysis. The utility of a face mask-based sampling approach was demonstrated by differentiating water, proteins, and virus-like particles sampled onto the mask. Data analysis using multivariate statistical algorithms enabled unambiguously classifying spectral signatures of individual components and biospecies. This approach has the potential to be extended towards the rapid detection of SARS-CoV-2-as shown herein for the example of virus-like particles which are morphologically equivalent to authentic virus-without any additional sample preparation or elaborate testing equipment at laboratory facilities. Therefore, this strategy may be implemented as a routine large-scale monitoring routine, e.g., at health care institutions, nursing homes, etc. ensuring the health and safety of medical personnel.
Subject(s)

Full text: Available Collection: International databases Database: MEDLINE Main subject: SARS-CoV-2 / Masks Type of study: Experimental Studies / Prognostic study Language: English Journal: Sci Rep Year: 2022 Document Type: Article Affiliation country: S41598-022-06335-z

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Main subject: SARS-CoV-2 / Masks Type of study: Experimental Studies / Prognostic study Language: English Journal: Sci Rep Year: 2022 Document Type: Article Affiliation country: S41598-022-06335-z