POS-677 COMPARISON BETWEEN SINGLE AND DOUBLE CUFFED TENCKHOFF CATHETER IN EARLY ONSET EXIT SITE INFECTION AND PERITONITIS - SINGLE CENTER EXPERIENCE
Kidney International Reports ; 7(2):S292, 2022.
Article in English | EMBASE | ID: covidwho-1707930
ABSTRACT

Introduction:

In Malaysia, the overall prevalence of Chronic Kidney Disease (CKD) is 15.48%1. The incidence of patients with end-stage renal disease (ESRD) requiring dialysis has been growing rapidly in Malaysia from 18 per million population (PMP) in 1993 to 231 PMP in 20132. From 2007 to 2016, the acceptance rate for both hemodialysis and peritoneal dialysis nearly doubled while the prevalence rate had increased by more than two-fold.3Early observational studies reported lower peritonitis rates with double versus single-cuffed catheters.4However, Eklund B et al. showed that there is no significant difference in terms of catheter survival, exit site infection and peritonitis.5Exit-site infection (ESI) is a common complication of peritoneal dialysis (PD) and is one of the important risk factors in PD-related peritonitis and technical failure.6In addition, exit site infection is an independent risk factor for early onset peritonitis. Early onset peritonitis on the other hand, is identified as an independent risk factor for mortality and technique failure in PD patients.7 Our objective of this study is to identify the incidence of exit site infection and early onset peritonitis among patients whom had their tenckhoff catheter inserted in Hospital Sultanah Bahiyah from January 2021 till June 2021.

Methods:

This is a single centered, retrospective observational study which examines the incidence of early onset exit site infection in the first 3 months and early onset peritonitis in the first 3 months for patients on newly inserted single or double cuffed tenckhoff catheters. All patients had their tenckhoff catheter inserted from 1stof January 2021 till 31stof June 2021 were recruited. The catheters are inserted by Nephrologists under Y-Tech peritoneoscope guidance in the operation theatre. Coiled Dacron cuffed catheters were used. I-series coiled PD catheter from MEDCOMP USA was used for single cuffed catheter while Argyle Curl Cath Peritoneal Catheters from MEDTRONIC USA was used for double cuffed catheter.

Results:

A total of 62 patients were included, 35 patients had double cuffed catheter inserted while 27 patients had single cuffed catheter inserted. One patient who had single cuffed catheter inserted was excluded from this study due to malfunctioning of tenckhoff catheter postoperatively. The mean age for single cuffed catheter and double cuffed catheter patients were 50.3 and 55.8 years old respectively. Among the single cuffed catheter patients, 12(44%) were female while 15(56%) were male. Among the double cuffed catheter patients, 19(54%) were female while 16(46%)were male. The incidence of exit site infection for single cuffed catheter was 2(8%) while double cuffed catheter was 6(17%) The incidence of early onset peritonitis for single cuffed catheter and double cuffed catheter were 4(15%) and 11(31%) respectively.

Conclusions:

There is a higher incidence of early onset exit site infection and early onset peritonitis among patients with double cuffed tenckhoff catheter. Our study has limitation due to small sample size as the study being conducted during the height of COVID19 pandemic. Further study would be needed to recruit more patients over longer duration to ascertain late onset exit site infection, peritonitis and the long term catheter survival among single and double cuffed tenckhoff catheter. No conflict of interest