Your browser doesn't support javascript.
Improving the Quantification of Colorimetric Signals in Paper-Based Immunosensors with an Open-Source Reader.
Russell, Steven M; Alba-Patiño, Alejandra; Vaquer, Andreu; Clemente, Antonio; de la Rica, Roberto.
  • Russell SM; Multidisciplinary Sepsis Group, Health Research Institute of the Balearic Islands (IdISBa), 07120 Palma de Mallorca, Spain.
  • Alba-Patiño A; Multidisciplinary Sepsis Group, Health Research Institute of the Balearic Islands (IdISBa), 07120 Palma de Mallorca, Spain.
  • Vaquer A; Chemistry Department, University of the Balearic Islands, 07122 Palma de Mallorca, Spain.
  • Clemente A; Multidisciplinary Sepsis Group, Health Research Institute of the Balearic Islands (IdISBa), 07120 Palma de Mallorca, Spain.
  • de la Rica R; Chemistry Department, University of the Balearic Islands, 07122 Palma de Mallorca, Spain.
Sensors (Basel) ; 22(5)2022 Feb 27.
Article in English | MEDLINE | ID: covidwho-1715645
ABSTRACT
Measuring the colorimetric signals produced by the biospecific accumulation of colorimetric probes and recording the results is a key feature for next-generation paper-based rapid tests. Manual processing of these tests is time-consuming and prone to a loss of accuracy when interpreting faint and patchy signals. Proprietary, closed-source readers and software companies offering automated smartphone-based assay readings have both been criticized for interoperability issues. Here, we introduce a minimal reader prototype composed of open-source hardware and open-source software that has the benefits of automatic assay quantification while avoiding the interoperability issues associated with closed-source readers. An image-processing algorithm was developed to automate the selection of an optimal region of interest and measure the average pixel intensity. When used to quantify signals produced by lateral flow immunoassays for detecting antibodies against SARS-CoV-2, results obtained with the proposed algorithm were comparable to those obtained with a manual method but with the advantage of improving the precision and accuracy when quantifying small spots or faint and patchy signals.
Subject(s)
Keywords

Full text: Available Collection: International databases Database: MEDLINE Main subject: Biosensing Techniques / COVID-19 Type of study: Diagnostic study Limits: Humans Language: English Year: 2022 Document Type: Article Affiliation country: S22051880

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Main subject: Biosensing Techniques / COVID-19 Type of study: Diagnostic study Limits: Humans Language: English Year: 2022 Document Type: Article Affiliation country: S22051880