Characterisation of Particle Size and Viability of SARS-CoV-2 Aerosols from a Range of Nebuliser Types Using a Novel Sampling Technique.
Paton, Susan; Clark, Simon; Spencer, Antony; Garratt, Isobel; Dinesh, Ikshitaa; Thompson, Katy-Anne; Bennett, Allan; Pottage, Thomas.
  • Paton S; UK Health Security Agency (UKHSA), Porton Down, Salisbury SP4 0JG, UK.
  • Clark S; UK Health Security Agency (UKHSA), Porton Down, Salisbury SP4 0JG, UK.
  • Spencer A; UK Health Security Agency (UKHSA), Porton Down, Salisbury SP4 0JG, UK.
  • Garratt I; UK Health Security Agency (UKHSA), Porton Down, Salisbury SP4 0JG, UK.
  • Dinesh I; UK Health Security Agency (UKHSA), Porton Down, Salisbury SP4 0JG, UK.
  • Thompson KA; UK Health Security Agency (UKHSA), Porton Down, Salisbury SP4 0JG, UK.
  • Bennett A; UK Health Security Agency (UKHSA), Porton Down, Salisbury SP4 0JG, UK.
  • Pottage T; UK Health Security Agency (UKHSA), Porton Down, Salisbury SP4 0JG, UK.
Viruses ; 14(3)2022 03 19.
Article in English | MEDLINE | ID: covidwho-1760847
ABSTRACT
Little is understood about the impact of nebulisation on the viability of SARS-CoV-2. In this study, a range of nebulisers with differing methods of aerosol generation were evaluated to determine SARS-CoV-2 viability following aerosolization. The aerosol particle size distribution was assessed using an aerosol particle sizer (APS) and SARS-CoV-2 viability was determined after collection into liquid media using All-Glass Impingers (AGI). Viable particles of SARS-CoV-2 were further characterised using the Collison 6-jet nebuliser in conjunction with novel sample techniques in an Andersen size-fractioning sampler to predict lung deposition profiles. Results demonstrate that all the tested nebulisers can generate stable, polydisperse aerosols (Geometric standard deviation (GSD) circa 1.8) in the respirable range (1.2 to 2.2 µm). Viable fractions (VF, units PFU/particle, the virus viability as a function of total particles produced) were circa 5 × 10-3. VF and spray factors were not significantly affected by relative humidity, within this system where aerosols were in the spray tube an extremely short time. The novel Andersen sample collection methods successfully captured viable virus particles across all sizes; with most particle sizes below 3.3 µm. Particle sizes, in MMAD (Mass Median Aerodynamic Diameters), were calculated from linear regression of log10-log10 transformed cumulative PFU data, and calculated MMADs accorded well with APS measurements and did not differ across collection method types. These data will be vital in informing animal aerosol challenge models, and infection prevention and control policies.
Subject(s)
Keywords

Full text: Available Collection: International databases Database: MEDLINE Main subject: SARS-CoV-2 / COVID-19 Type of study: Experimental Studies / Prognostic study Limits: Animals Language: English Year: 2022 Document Type: Article Affiliation country: V14030639