Your browser doesn't support javascript.
Oxygen saturation measurements using novel diffused reflectance with hyperspectral imaging: Towards facile COVID-19 diagnosis.
El-Sharkawy, Yasser H; Aref, Mohamed Hisham; Elbasuney, Sherif; Radwan, Sara M; El-Sayyad, Gharieb S.
  • El-Sharkawy YH; Head of Biomedical Engineering Department, Military Technical College, Egyptian Armed Forces, Cairo, Egypt.
  • Aref MH; Biomedical Engineering Department, Military Technical College, Egyptian Armed Forces, Cairo, Egypt.
  • Elbasuney S; Head of Nanotechnology Research Center, Military Technical College, Egyptian Armed Forces, Cairo, Egypt.
  • Radwan SM; Biochemistry Department, Faculty of Pharmacy, Ain Shams University, Cairo, Egypt.
  • El-Sayyad GS; Microbiology and Immunology Department, Faculty of Pharmacy, Galala University, New Galala city, Suez, Egypt.
Opt Quantum Electron ; 54(5): 322, 2022.
Article in English | MEDLINE | ID: covidwho-1826748
ABSTRACT
Oxygen saturation level plays a vital role in screening, diagnosis, and therapeutic assessment of disease's assortment. There is an urgent need to design and implement early detection devices and applications for the COVID-19 pandemic; this study reports on the development of customized, highly sensitive, non-invasive, non-contact diffused reflectance system coupled with hyperspectral imaging for mapping subcutaneous blood circulation depending on its oxygen saturation level. The forearm of 15 healthy adult male volunteers with age range of (20-38 years) were illuminated via a polychromatic light source of a spectrum range 400-980 nm. Each patient had been scanned five times to calculate the mean spectroscopic reflectance images using hyperspectral camera. The customized signal processing algorithm includes normalization and moving average filter for noise removal. Afterward, employing K-means clustering for image segmentation to assess the accuracy of blood oxygen saturation (SpO2) levels. The reliability of the developed diffused reflectance system was verified with the ground truth technique, a standard pulse oximeter. Non-invasive, non-contact diffused reflectance spectrum demonstrated maximum signal variation at 610 nm according to SpO2 level. Statistical analysis (mean, standard deviation) of diffused reflectance hyperspectral images at 610 nm offered precise calibrated measurements to the standard pulse oximeter. Diffused reflectance associated with hyperspectral imaging is a prospective technique to assist with phlebotomy and vascular approach. Additionally, it could permit future surgical or pharmacological intercessions that titrate or limit ischemic injury continuously. Furthermore, this technique could offer a fast reliable indication of SpO2 levels for COVID-19 diagnosis.
Keywords

Full text: Available Collection: International databases Database: MEDLINE Type of study: Diagnostic study / Observational study / Prognostic study Language: English Journal: Opt Quantum Electron Year: 2022 Document Type: Article Affiliation country: S11082-022-03658-z

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Type of study: Diagnostic study / Observational study / Prognostic study Language: English Journal: Opt Quantum Electron Year: 2022 Document Type: Article Affiliation country: S11082-022-03658-z