Your browser doesn't support javascript.
All-in-One Digital Microfluidics System for Molecular Diagnosis with Loop-Mediated Isothermal Amplification.
Hu, Siyi; Jie, Yuhan; Jin, Kai; Zhang, Yifan; Guo, Tianjie; Huang, Qi; Mei, Qian; Ma, Fuqiang; Ma, Hanbin.
  • Hu S; CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China.
  • Jie Y; Guangdong ACXEL Micro & Nano Tech Co., Ltd., Foshan 528000, China.
  • Jin K; CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China.
  • Zhang Y; CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China.
  • Guo T; CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China.
  • Huang Q; CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China.
  • Mei Q; CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China.
  • Ma F; CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China.
  • Ma H; CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China.
Biosensors (Basel) ; 12(5)2022 May 11.
Article in English | MEDLINE | ID: covidwho-1869468
ABSTRACT
In this study, an "all-in-one" digital microfluidics (DMF) system was developed for automatic and rapid molecular diagnosis and integrated with magnetic bead-based nucleic acid extraction, loop-mediated isothermal amplification (LAMP), and real-time optical signal monitoring. First, we performed on- and off-chip comparison experiments for the magnetic bead nucleic acid extraction module and LAMP amplification function. The extraction efficiency for the on-chip test was comparable to that of conventional off-chip methods. The processing time for the automatic on-chip workflow was only 23 min, which was less than that of the conventional methods of 28 min 45 s. Meanwhile, the number of samples used in on-chip experiments was significantly smaller than that used in off-chip experiments; only 5 µL of E. coli samples was required for nucleic acid extraction, and 1 µL of the nucleic acid template was needed for the amplification reaction. In addition, we selected SARS-CoV-2 nucleic acid reference materials for the nucleic acid detection experiment, demonstrating a limit of detection of 10 copies/µL. The proposed "all-in-one" DMF system provides an on-site "sample to answer" time of approximately 60 min, which can be a powerful tool for point-of-care molecular diagnostics.
Subject(s)
Keywords

Full text: Available Collection: International databases Database: MEDLINE Main subject: Nucleic Acids / COVID-19 Type of study: Diagnostic study Limits: Humans Language: English Year: 2022 Document Type: Article Affiliation country: Bios12050324

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Main subject: Nucleic Acids / COVID-19 Type of study: Diagnostic study Limits: Humans Language: English Year: 2022 Document Type: Article Affiliation country: Bios12050324