Your browser doesn't support javascript.
Air quality in an air ventilated fitness center reopening for pilot study during COVID-19 pandemic lockdown.
Huessler, Eva-Maria; Hüsing, Anika; Vancraeyenest, Markus; Jöckel, Karl-Heinz; Schröder, Bernadette.
  • Huessler EM; Institute of Medical Informatics, Biometry and Epidemiology (IMIBE), University Hospital Essen, Hufelandstraße 35, 45147 Essen, Germany.
  • Hüsing A; Institute of Medical Informatics, Biometry and Epidemiology (IMIBE), University Hospital Essen, Hufelandstraße 35, 45147 Essen, Germany.
  • Vancraeyenest M; FitX Verwaltung GmbH, Stoppenberger Straße 61, 45141 Essen, Germany.
  • Jöckel KH; Institute of Medical Informatics, Biometry and Epidemiology (IMIBE), University Hospital Essen, Hufelandstraße 35, 45147 Essen, Germany.
  • Schröder B; Institute of Medical Informatics, Biometry and Epidemiology (IMIBE), University Hospital Essen, Hufelandstraße 35, 45147 Essen, Germany.
Build Environ ; 219: 109180, 2022 Jul 01.
Article in English | MEDLINE | ID: covidwho-1944379
ABSTRACT
During COVID-19 lockdowns less people were able to fulfill the WHO recommendations on physical activity. Also, fitness centers were associated to SARS-CoV-2 superspreader events. However, the risk of infection can be strongly reduced by outdoor air ventilation. To investigate whether a reopening of fitness centers can be justified, CO 2 concentration was measured during four days in a fitness center. Except for one room, the observed CO 2 concentrations were mainly under 800 ppm, which stands for high air quality. The strong decrease of CO 2 concentration during the 15 min evacuations following each hour of workout, speaks for the functionality of the ventilation system. In particular, the number of people present in the studio has a strong impact on the estimated CO 2 value. In a linear mixed model, an additional CO 2 concentration of 2.24 ppm (95 % confidence interval [2.04, 2.43]) was estimated for this setting with a total volume of 4065 m 3 in the fitness center and a possible air change rate per hour up to 10. This means, that for 45 visitors, 100 ppm can be added to the predicted concentration. To summarize, a combination of ventilation, restriction of the number of visitors and surveying the CO 2 concentration allowing for further restrictions in case of need, seems to be an adequate means to reduce the risk of SARS-CoV-2 infection in fitness centers.
Keywords

Full text: Available Collection: International databases Database: MEDLINE Type of study: Observational study / Prognostic study Language: English Journal: Build Environ Year: 2022 Document Type: Article Affiliation country: J.buildenv.2022.109180

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Type of study: Observational study / Prognostic study Language: English Journal: Build Environ Year: 2022 Document Type: Article Affiliation country: J.buildenv.2022.109180