Your browser doesn't support javascript.
Assessment of the Diagnostic Performance of a Novel SARS-CoV-2 Antigen Sealing Tube Test Strip (Colloidal Gold) as Point-of-Care Surveillance Test.
Medoro, Alessandro; Davinelli, Sergio; Voccola, Serena; Cardinale, Gaetano; Passarella, Daniela; Marziliano, Nicola; Intrieri, Mariano.
  • Medoro A; Department of Medicine and Health Sciences "V. Tiberio", University of Molise, 86100 Campobasso, Italy.
  • Davinelli S; Department of Medicine and Health Sciences "V. Tiberio", University of Molise, 86100 Campobasso, Italy.
  • Voccola S; Centro Diagnostico Delta S.r.l., Consorzio Sannio Tech, Apollosa, 82030 Benevento, Italy.
  • Cardinale G; Centro Diagnostico Delta S.r.l., Consorzio Sannio Tech, Apollosa, 82030 Benevento, Italy.
  • Passarella D; Department of Medicine and Health Sciences "V. Tiberio", University of Molise, 86100 Campobasso, Italy.
  • Marziliano N; Department of Medicine and Health Sciences "V. Tiberio", University of Molise, 86100 Campobasso, Italy.
  • Intrieri M; Clinical Pathology Laboratory, ASST Rhodense, Rho, 20017 Milan, Italy.
Diagnostics (Basel) ; 12(5)2022 May 21.
Article in English | MEDLINE | ID: covidwho-1953133
ABSTRACT
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variant outbreaks have highlighted the need of antigen-detecting rapid diagnostic tests (Ag-RDTs) that can be used at the point-of-care (POC). Although many Ag-RDTs have been approved for SARS-CoV-2 detection, studies demonstrating the clinical performance of Ag-RDTs against variants of concern, especially the new Omicron variant, are limited. The aim of this study was to evaluate the diagnostic sensitivity and specificity of the AMAZING COVID-19 Antigen Sealing Tube Test Strip (Colloidal Gold) in 584 early symptomatic and asymptomatic participants (age range 0-90 years). The performance of this Ag-RDT was assessed by comparing its results with reverse transcription RT-PCR (rRT-PCR). One hundred twenty positive samples were also analyzed with rRT-PCR to discriminate Omicron and Delta/Kappa variants (72.50% Omicron; 27.50% Delta/Kappa). Overall, the Ag-RDT showed high positive and negative percent values of 92.52% (95% CI, 86.61-95.95%) and 98.05% (95% CI, 96.41-98.95%), respectively, as well as an overall diagnostic accuracy of 96.92% (95% CI, 95.17-98.16%). Taken together, these data indicate that this inexpensive and simple-to-use Ag-RDT presents excellent analytical performance and can reliably detect Omicron and Delta/Kappa variants.
Keywords

Full text: Available Collection: International databases Database: MEDLINE Type of study: Diagnostic study / Experimental Studies / Prognostic study Topics: Variants Language: English Year: 2022 Document Type: Article Affiliation country: Diagnostics12051279

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Type of study: Diagnostic study / Experimental Studies / Prognostic study Topics: Variants Language: English Year: 2022 Document Type: Article Affiliation country: Diagnostics12051279