Design of Uninterrupted Oxygen Supply for Field Hospital in Jordan
13th International Conference on Information and Communication Systems, ICICS 2022
; : 432-435, 2022.
Article
in English
| Scopus | ID: covidwho-1973478
ABSTRACT
Field hospitals were a great help in global pandemics and catastrophes such as earthquakes and the spread of airborne viruses. This study focused on the design of an interrupted oxygen supply since continuous oxygen provision for covid-19 patients is a huge problem facing field hospitals around the world, three methods to avoid any oxygen supply interruptions are discussed, where the outlet of the oxygen concentrator is lowered to 4.5 bar, and the outlet of the liquid oxygen vaporizer is regulated at 4.25 bar, and the outlet of the oxygen cylinders is set to 4 bars, a final one-way valve connecting the three lines of oxygen which are set to 4 bars. © 2022 IEEE.
Full text:
Available
Collection:
Databases of international organizations
Database:
Scopus
Language:
English
Journal:
13th International Conference on Information and Communication Systems, ICICS 2022
Year:
2022
Document Type:
Article
Similar
MEDLINE
...
LILACS
LIS