Efficacy of McGRATH®MAC videolaryngoscope blade 1 for tracheal intubation in small children: a randomized controlled clinical study.
Masui, Katsuhide; Asai, Takashi; Saito, Tomoyuki; Okuda, Yasuhisa.
  • Masui K; Department of Anesthesiology, Dokkyo Medical University Saitama Medical Center, 2-1-50 Minami-Koshigaya, Koshigaya City, Saitama, 343-8555, Japan. km2525mk2525@gmail.com.
  • Asai T; Department of Anesthesiology, Dokkyo Medical University Saitama Medical Center, 2-1-50 Minami-Koshigaya, Koshigaya City, Saitama, 343-8555, Japan.
  • Saito T; Department of Anesthesiology, Dokkyo Medical University Saitama Medical Center, 2-1-50 Minami-Koshigaya, Koshigaya City, Saitama, 343-8555, Japan.
  • Okuda Y; Department of Anesthesiology, Dokkyo Medical University Saitama Medical Center, 2-1-50 Minami-Koshigaya, Koshigaya City, Saitama, 343-8555, Japan.
J Anesth ; 2023 Jun 13.
Article in English | MEDLINE | ID: covidwho-20239431
ABSTRACT

BACKGROUND:

Videolaryngoscopes may not be as effective in small children as they are in older children and in adults. The size 1 blade is commercially available for the McGRATH®MAC videolaryngoscope (Covidien, Medtronic, Tokyo, Japan), but its efficacy in comparison with a Macintosh laryngoscope blade 1 is not known.

AIM:

The main aim of this study was to assess the efficacy of McGrath®MAC blade 1 in comparison with a conventional Macintosh laryngoscope blade 1, in children aged less than 24 months.

METHODS:

Thirty-eight children aged less than 24 months were randomly allocated to one of two groups, and tracheal intubation was attempted using either a direct laryngoscope with a Macintosh blade 1 or a videolaryngoscope with a McGRATH®MAC blade 1. In another 12 children aged 2-4 years, the same comparisons were made with blade 2. The primary outcome measure was time to tracheal intubation using a size 1 blade.

RESULTS:

Tracheal intubation took significantly longer with a McGRATH®MAC blade 1 (median (interquartile range) 38.0 (31.8-43.5) s) than with the Macintosh blade 1(27.4 (25.9-29.2) s) (p < 0.0001; median difference (95% CI for the median difference) 10.6 (6.4-14.0) s), mainly due to difficulty in advancing a tube into the trachea. No significant difference was observed for the size 2.

CONCLUSIONS:

In small children without predicted difficult airways, time to intubate the trachea was significantly longer for a McGRATH®MAC blade 1 than a Macintosh blade 1. CLINICAL TRIAL REGISTRATION jRCT1032220366.
Keywords

Full text: Available Collection: International databases Database: MEDLINE Type of study: Experimental Studies / Prognostic study / Randomized controlled trials Language: English Journal subject: Anesthesiology Year: 2023 Document Type: Article Affiliation country: S00540-023-03207-2

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Type of study: Experimental Studies / Prognostic study / Randomized controlled trials Language: English Journal subject: Anesthesiology Year: 2023 Document Type: Article Affiliation country: S00540-023-03207-2