Your browser doesn't support javascript.
[Evaluation of the Aspergillus Galactomannan ag VircliaR Monotest test as an alternative to Platelia™ Aspergillus EIA kit]. / Evaluación de la prueba Aspergillus Galactomannan Ag VircliaR Monotest como alternativa a kit Platelia™ Aspergillus EIA.
Troncoso C, Rubi; Sepúlveda F, Claudia; Sepúlveda P, Evelyn; Guzmán U, Camila; Morales G, Marcela; Tapia P, Cecilia.
  • Troncoso C R; Laboratorio de Especialidad, Clínica Dávila, Chile.
  • Sepúlveda F C; Laboratorio de Especialidad, Clínica Dávila, Chile.
  • Sepúlveda P E; Laboratorio Vidaíntegra-Omesa, Empresa Microbac, Ltda, Chile.
  • Guzmán U C; Laboratorio de Especialidad, Clínica Dávila, Chile.
  • Morales G M; Empresa Microbac Ltda, Chile.
  • Tapia P C; Laboratorio de Especialidad, Clínica Dávila, Chile.
Rev Chilena Infectol ; 39(3): 248-253, 2022 06.
Article in Spanish | MEDLINE | ID: covidwho-2044073
ABSTRACT

BACKGROUND:

The Aspergillus Galactomannan Ag Virclia® (GMVClia) test is a monotest and automated galactomannan technique based on chemiluminescent immunoassay (CLIA).

AIM:

To evaluate the performance of the GM-VClia test in serum and bronchioalveolar lavage (BAL) samples previously processed with the Platelia ™ Aspergillus EIA kit (GM-Plat).

METHODS:

56 samples of serum 40 from BAL (some of them with galactomaman determination in both samples), from patients with pulmonary diseases, hematological diseases, SLE, Covid-19 and tumors, among others, were studied. Thirteen patients had invasive aspergillosis (1 proven and 12 probable).

RESULTS:

The correlation between both methods for serum and BAL was r = 0.8861 p < 0.0001 and r = 0.6368 p < 0.001, respectively. There was a global concordance of 67.7% (65/96), being 85.7% (48/56) in sera and 42.5.0% (14/49) in BAL. By raising the cut-off point in LBA by GM-VClia, the agreement increased to 85.7%.

CONCLUSION:

A greater correlation and concordance was observed in sera than in BAL. The GM-VClia kit had a higher sensitivity and NPV than the GM-Plat kit. The disadvantages of GM-VClia are the "doubtful" category, which makes interpretation difficult and that with the current cut-off points in LBA the correlation with GM-Plat is lower. The advantages are its greater sensitivity, ease of processing and faster results.
Subject(s)

Full text: Available Collection: International databases Database: MEDLINE Main subject: COVID-19 Type of study: Diagnostic study / Experimental Studies Limits: Humans Language: Spanish Journal: Rev Chilena Infectol Year: 2022 Document Type: Article Affiliation country: S0716-10182022000200248

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Main subject: COVID-19 Type of study: Diagnostic study / Experimental Studies Limits: Humans Language: Spanish Journal: Rev Chilena Infectol Year: 2022 Document Type: Article Affiliation country: S0716-10182022000200248