Your browser doesn't support javascript.
Positivization time of a COVID-19 rapid antigen self-test predicts SARS-CoV-2 viral load: a proof of concept.
Salvagno, Gian Luca; Henry, Brandon M; Bongiovanni, Giulio; De Nitto, Simone; Pighi, Laura; Lippi, Giuseppe.
  • Salvagno GL; Section of Clinical Biochemistry, University of Verona, Verona, Italy.
  • Henry BM; Service of Laboratory Medicine, Pederzoli Hospital, Peschiera del Garda, Italy.
  • Bongiovanni G; Clinical Laboratory, Division of Nephrology and Hypertension, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA.
  • De Nitto S; Medical Direction, Pederzoli Hospital, Peschiera del Garda, Italy.
  • Pighi L; Section of Clinical Biochemistry, University of Verona, Verona, Italy.
  • Lippi G; Service of Laboratory Medicine, Pederzoli Hospital, Peschiera del Garda, Italy.
Clin Chem Lab Med ; 2022 Nov 01.
Article in English | MEDLINE | ID: covidwho-2235190
ABSTRACT

OBJECTIVES:

This proof of concept study was aimed to validate the hypothesis that the time of positivization of SARS-CoV-2 self-performed rapid diagnostic tests (RDTs) may reflect the actual viral load in the specimen.

METHODS:

A SARS-CoV-2 positive sample with high viral load was diluted and concomitantly assayed with molecular assay (Xpert Xpress SARS-CoV-2) and RDT (COVID-VIRO ALL IN RDT). The (mean cycle threshold; Ct) values and RDT positivization times of these dilutions were plotted and interpolated by calculating the best fit. The parameters of this equation were then used for converting the positivization times into RDT-estimated SARS-CoV-2 Ct values in routine patient samples.

RESULTS:

The best fit between measured and RDT-estimated Ct values could be achieved with a 2-degree polynomial curve. The RDT-estimated Ct values exhibited high correlation (r=0.996) and excellent Deming fit (y=1.01 × x - 0.18) with measured Ct values. In 30 consecutive patients with positive RDT test, the correlation between RDT positivization time and measured Ct value was r=0.522 (p=0.003). The correlation of RDT-estimated and measured Ct values slightly improved to 0.577 (Deming fit y=0.44 × x + 11.08), displaying a negligible bias (1.0; 95% CI, -0.2 to 2.2; p=0.105). Concordance of RDT-estimated and measured Ct values at the <20 cut-off was 80%, with 0.84 sensitivity and 0.73 specificity.

CONCLUSIONS:

This proof of concept study demonstrates the potential feasibility of using RDTs for garnering information on viral load in patients with acute SARS-CoV-2 infection.
Keywords

Full text: Available Collection: International databases Database: MEDLINE Type of study: Diagnostic study / Prognostic study Language: English Journal subject: Chemistry, Clinical / Laboratory Techniques and procedures Year: 2022 Document Type: Article Affiliation country: Cclm-2022-0873

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Type of study: Diagnostic study / Prognostic study Language: English Journal subject: Chemistry, Clinical / Laboratory Techniques and procedures Year: 2022 Document Type: Article Affiliation country: Cclm-2022-0873