CoronaVac, BNT162b2 and heterologous COVID-19 vaccine outcomes in patients with ventricular assist device.
Karahan, Mehmet; Kervan, Umit; Kocabeyoglu, Sinan Sabit; Sert, Dogan Emre; Tekce, Yasemin Tezer; Yavuz, Omer Abdullah; Kucuker, Seref Alp; Ozatik, Mehmet Ali; Catav, Zeki; Sener, Erol.
  • Karahan M; Cardiovascular Surgery, Ankara City Hospital, Cankaya, Ankara, Turkiye.
  • Kervan U; Cardiovascular Surgery, Ankara City Hospital, Cankaya, Ankara, Turkiye.
  • Kocabeyoglu SS; Cardiovascular Surgery, Ankara City Hospital, Cankaya, Ankara, Turkiye.
  • Sert DE; Cardiovascular Surgery, Ankara City Hospital, Cankaya, Ankara, Turkiye.
  • Tekce YT; Infectious Diseases, Ankara City Hospital, Cankaya, Ankara, Turkiye.
  • Yavuz OA; Cardiovascular Surgery, Ankara City Hospital, Cankaya, Ankara, Turkiye.
  • Kucuker SA; Cardiovascular Surgery, Ankara City Hospital, Cankaya, Ankara, Turkiye.
  • Ozatik MA; Cardiovascular Surgery, Ankara City Hospital, Cankaya, Ankara, Turkiye.
  • Catav Z; Cardiovascular Surgery, Ankara City Hospital, Cankaya, Ankara, Turkiye.
  • Sener E; Cardiovascular Surgery, Ankara City Hospital, Cankaya, Ankara, Turkiye.
Int J Artif Organs ; 46(1): 15-21, 2023 Jan.
Article in English | MEDLINE | ID: covidwho-2162167
ABSTRACT

BACKGROUND:

A consensus has not yet been reached regarding which COVID-19 vaccine program should be applied in patients with ventricular assist device (VAD). Our aim was to assess the clinical outcome of inactivated, mRNA and heterologous vaccine program in patient with VAD.

METHODS:

In this retrospective and cross-sectional study; adult patients who underwent VAD implantation between January 2012 and September 2021 and received any vaccine that were used in Republic of Türkiye for COVID-19, were included. The patients were divided into three groups according to the type of vaccine; "inactivated," "mRNA" and "heterologous." Clinical outcomes were analyzed.

RESULTS:

Eighteen patients were in each group in the "inactivated," "mRNA" and "heterologous" groups. Mean age was 51.6 ± 12 years in "inactivated" group, 42.5 ± 15.5 years in "mRNA" group and 41.1 ± 15.4 years in "heterologous" group. There was no significant difference between the groups in age, gender, body surface area, body mass index and etiology (p > 0.05). After last dose of vaccines, the number of patients had COVID-19 positive test were three (16.7%), one (5.6%), and two (11.1%) in "inactivated," "mRNA" and "heterologous" groups, respectively. Pump thrombosis was seen in two patients in "mRNA" group and one patient in "heterologous" group. No pump thrombosis was seen in "inactivated" group. COVID-19-related death or intubation was not observed.

CONCLUSION:

All vaccine that used for COVID-19 are safe and effective in patients with VAD. In countries that give priority to inactivated vaccines, mRNA vaccines may then be made as boosters.
Subject(s)
Keywords

Full text: Available Collection: International databases Database: MEDLINE Main subject: Heart-Assist Devices / COVID-19 Type of study: Etiology study / Experimental Studies / Observational study / Prognostic study / Randomized controlled trials Topics: Vaccines Limits: Adult / Humans / Middle aged Language: English Journal: Int J Artif Organs Year: 2023 Document Type: Article

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Main subject: Heart-Assist Devices / COVID-19 Type of study: Etiology study / Experimental Studies / Observational study / Prognostic study / Randomized controlled trials Topics: Vaccines Limits: Adult / Humans / Middle aged Language: English Journal: Int J Artif Organs Year: 2023 Document Type: Article