Your browser doesn't support javascript.
An Evaluation of Serological Tests to Determine Postvaccinal Immunity to SARS-CoV-2 by mRNA Vaccines.
Iglesias García, Graciela; Díaz Rodríguez, Ángel; Díaz Fernández, Beatriz; Cuello Estrada, Carmela; García Ferreiro, Tania; Crespo García, Noelia; Seco-Calvo, Jesús.
  • Iglesias García G; Institute of Biomedicine (IBIOMED), Campus of Vegazana, University of Leon, 24071 Leon, Spain.
  • Díaz Rodríguez Á; Institute of Biomedicine (IBIOMED), Campus of Vegazana, University of Leon, 24071 Leon, Spain.
  • Díaz Fernández B; Bembibre Health Center, University of Leon, Carbajal Street 1, 24300 Bembibre, Spain.
  • Cuello Estrada C; Arturo Eyries Center, Puerto Rico Street 1, 47014 Valladolid, Spain.
  • García Ferreiro T; Bembibre Health Center, University of Leon, Carbajal Street 1, 24300 Bembibre, Spain.
  • Crespo García N; Bembibre Health Center, University of Leon, Carbajal Street 1, 24300 Bembibre, Spain.
  • Seco-Calvo J; Bembibre Health Center, University of Leon, Carbajal Street 1, 24300 Bembibre, Spain.
J Clin Med ; 11(24)2022 Dec 19.
Article in English | MEDLINE | ID: covidwho-2166621
ABSTRACT

BACKGROUND:

The duration of the protective efficacy of vaccines against SARS-CoV-2 is unknown. Thus, an evaluation of the clinical performance of available tests is required.

OBJECTIVES:

To evaluate the clinical performance of LFIA immunoassay compared to ELIA and CLIA immunoassays available in Europe for the detection of IgG antibodies generated by mRNA vaccines against SARS-CoV-2.

METHODS:

Two automated immunoassays (the EUROIMMUN anti-SARS-CoV-2 IgG S1 ELISA and the LIAISON de Diasorin anti-SARS-CoV-2 IgG S1/S2 test) and a lateral flow immunoassay (the Livzon LFIA anti-SARS-CoV-2 IgG S test) were tested. We analyzed 300 samples distributed in three groups 100 subjects aged over 18 years and under 45 years, 100 subjects aged between 45 and 65 years, and 100 subjects aged over 65 years. The samples were collected before vaccination; at 21 days; and then at 1, 2, 3, and 6 months after vaccination. The sensitivity, specificity, positive predictive value, negative predictive value, positive probability quotient, negative probability quotient, and concordance (kappa index) were calculated for each serological test.

RESULTS:

The maximum sensitivity values for IgG were 98.7%, 98.1%, and 97.8% for the EUROIMMUN ELISA, Abbott CLIA, and Livzon LFIA tests, respectively, and the maximum specificity values for IgG were 99.4%, 99.9%%, and 98.4% for the ELISA, CLIA, and LFIA tests, respectively, at the third month after vaccination, representing a decrease in the antibody levels after the sixth month. The best agreement was observed between the ELISA and CLIA tests at 100% (k = 1.00). The agreement between the ELIA, CLIA, and LFIA tests was 99% (k = 0.964) at the second and third month after vaccination. Seroconversion was faster and more durable in the younger age groups.

CONCLUSION:

Our study examined the equivalent and homogeneous clinical performance for IgG of three immunoassays after vaccination and found LFIA to be the most cost-effective, reliable, and accurate for routine use in population seroconversion and seroprevalence studies.
Keywords

Full text: Available Collection: International databases Database: MEDLINE Type of study: Diagnostic study / Experimental Studies / Observational study / Prognostic study / Randomized controlled trials Topics: Vaccines Language: English Year: 2022 Document Type: Article Affiliation country: Jcm11247534

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Type of study: Diagnostic study / Experimental Studies / Observational study / Prognostic study / Randomized controlled trials Topics: Vaccines Language: English Year: 2022 Document Type: Article Affiliation country: Jcm11247534