Your browser doesn't support javascript.
Whole-blood Point-of-Care Activated Partial Thromboplastin Time Ratio (APR) is not Accurate Enough to Monitor Heparin Therapy in Patients with Severe Respiratory Failure Secondary to SARS-Cov-2 Infection Supported with Veno-Venous Extracorporeal Membrane Oxygenation (VV-ECMO).
Aston, Daniel; Besser, Martin; Goddard, Ben; Maggs, Nicholas; Ahmed, Hassan; Falter, Florian.
  • Aston D; Department of Anaesthesia and Critical Care, Royal Papworth Hospital, Cambridge Biomedical Campus, Cambridge, UK.
  • Besser M; Division of Clinical Haematology and Blood Transfusion, Cambridge University Hospitals, Cambridge, UK.
  • Goddard B; Department of Clinical Perfusion, Royal Papworth Hospital, Cambridge Biomedical Campus, Cambridge, UK.
  • Maggs N; Department of Clinical Perfusion, Royal Papworth Hospital, Cambridge Biomedical Campus, Cambridge, UK.
  • Ahmed H; Department of Anaesthesia and Intensive Care, 4472Leeds Teaching Hospitals NHS Trust, Leeds, UK.
  • Falter F; Department of Anaesthesia and Critical Care, Royal Papworth Hospital, Cambridge Biomedical Campus, Cambridge, UK.
Clin Appl Thromb Hemost ; 28: 10760296221148162, 2022.
Article in English | MEDLINE | ID: covidwho-2195099
ABSTRACT
Support with VV-ECMO requires anticoagulation with unfractionated heparin to prevent thrombotic complications. This must be monitored due to bleeding risk. A point-of-care (POC) method of testing aPTT and APR was evaluated for agreement with laboratory methods. In a prospective observational study, patients supported on VV-ECMO as a result of severe respiratory failure secondary to Covid-19 infection were given heparin as part of standard therapy. The aPTT was measured (i) at the bedside using the Hemochron Signature Elite device and (ii) at the hospital laboratory. Duplicate results were compared. Agreement between the POC and laboratory tests was poor, as assessed using the Bland-Altman method. The maximum difference between POC and laboratory methods was 133% and the minimum was 0%. Overall bias was 7.3% and limits of agreement were between -43.8% and 58.5%. Correlation increased when results were normalised to platelet count and creatinine. This POC test is insufficiently accurate for use as the primary method of heparin monitoring in patients requiring VV-ECMO for Covid-19. Platelets and renal function may influence the result of this whole blood POC test.
Subject(s)
Keywords

Full text: Available Collection: International databases Database: MEDLINE Main subject: Respiratory Insufficiency / Extracorporeal Membrane Oxygenation / COVID-19 Type of study: Experimental Studies / Observational study / Prognostic study Topics: Long Covid Limits: Humans Language: English Journal: Clin Appl Thromb Hemost Journal subject: Vascular Diseases Year: 2022 Document Type: Article Affiliation country: 10760296221148162

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Main subject: Respiratory Insufficiency / Extracorporeal Membrane Oxygenation / COVID-19 Type of study: Experimental Studies / Observational study / Prognostic study Topics: Long Covid Limits: Humans Language: English Journal: Clin Appl Thromb Hemost Journal subject: Vascular Diseases Year: 2022 Document Type: Article Affiliation country: 10760296221148162