Your browser doesn't support javascript.
Thermophysiological and Perceptual Responses of Amateur Healthcare Workers: Impacts of Ambient Condition, Inner-Garment Insulation and Personal Cooling Strategy.
Zhao, Yingying; Su, Meng; Meng, Xin; Liu, Jiying; Wang, Faming.
  • Zhao Y; School of Thermal Engineering, Shandong Jianzhu University, Jinan 250101, China.
  • Su M; School of Thermal Engineering, Shandong Jianzhu University, Jinan 250101, China.
  • Meng X; School of Thermal Engineering, Shandong Jianzhu University, Jinan 250101, China.
  • Liu J; School of Thermal Engineering, Shandong Jianzhu University, Jinan 250101, China.
  • Wang F; Department of Biosystems, Katholieke Universiteit Leuven, 3001 Leuven, Belgium.
Int J Environ Res Public Health ; 20(1)2022 12 29.
Article in English | MEDLINE | ID: covidwho-2246783
ABSTRACT
While personal protective equipment (PPE) protects healthcare workers from viruses, it also increases the risk of heat stress. In this study, the effects of environmental heat stress, the insulation of the PPE inner-garment layer, and the personal cooling strategy on the physiological and perceptual responses of PPE-clad young college students were evaluated. Three levels of wet bulb globe temperatures (WBGT = 15 °C, 28 °C, and 32 °C) and two types of inner garments (0.37 clo and 0.75 clo) were chosen for this study. In an uncompensable heat stress environment (WBGT = 32 °C), the effects of two commercially available personal cooling systems, including a ventilation cooling system (VCS) and an ice pack cooling system (ICS) on the heat strain mitigation of PPE-clad participants were also assessed. At WBGT = 15 °C with 0.75 clo inner garments, mean skin temperatures were stabilized at 31.2 °C, Hskin was 60-65%, and HR was about 75.5 bpm, indicating that the working scenario was on the cooler side. At WBGT = 28 °C, Tskin plateaued at approximately 34.7 °C, and the participants reported "hot" thermal sensations. The insulation reduction in inner garments from 0.75 clo to 0.37 clo did not significantly improve the physiological thermal comfort of the participants. At WBGT = 32 °C, Tskin was maintained at 35.2-35.7 °C, Hskin was nearly 90% RH, Tcore exceeded 37.1 °C, and the mean HR was 91.9 bpm. These conditions indicated that such a working scenario was uncompensable, and personal cooling to mitigate heat stress was required. Relative to that in NCS (no cooling), the mean skin temperatures in ICS and VCS were reduced by 0.61 °C and 0.22 °C, respectively, and the heart rates were decreased by 10.7 and 8.5 bpm, respectively. Perceptual responses in ICS and VCS improved significantly throughout the entire field trials, with VCS outperforming ICS in the individual cooling effect.
Subject(s)
Keywords

Full text: Available Collection: International databases Database: MEDLINE Main subject: Body Temperature Regulation / Heat Stress Disorders Type of study: Experimental Studies / Prognostic study Limits: Humans Language: English Year: 2022 Document Type: Article Affiliation country: Ijerph20010612

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Main subject: Body Temperature Regulation / Heat Stress Disorders Type of study: Experimental Studies / Prognostic study Limits: Humans Language: English Year: 2022 Document Type: Article Affiliation country: Ijerph20010612