Your browser doesn't support javascript.
Implementation of an Environmental Cleaning Protocol in Hospital Critical Areas Using a UV-C Disinfection Robot.
Casini, Beatrice; Tuvo, Benedetta; Scarpaci, Michela; Totaro, Michele; Badalucco, Federica; Briani, Silvia; Luchini, Grazia; Costa, Anna Laura; Baggiani, Angelo.
  • Casini B; Department of Translational Research and the New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy.
  • Tuvo B; Department of Translational Research and the New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy.
  • Scarpaci M; Department of Translational Research and the New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy.
  • Totaro M; Department of Translational Research and the New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy.
  • Badalucco F; Department of Translational Research and the New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy.
  • Briani S; Hospital Management, University Hospital of Pisa, 56126 Pisa, Italy.
  • Luchini G; Hospital Management, University Hospital of Pisa, 56126 Pisa, Italy.
  • Costa AL; Department of Translational Research and the New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy.
  • Baggiani A; Department of Translational Research and the New Technologies in Medicine and Surgery, University of Pisa, 56126 Pisa, Italy.
Int J Environ Res Public Health ; 20(5)2023 02 28.
Article in English | MEDLINE | ID: covidwho-2253939
ABSTRACT
Improving the cleaning and disinfection of high-touch surfaces is one of the core components of reducing healthcare-associated infections. The effectiveness of an enhanced protocol applying UV-C irradiation for terminal room disinfection between two successive patients was evaluated. Twenty high-touch surfaces in different critical areas were sampled according to ISO 14698-1, both immediately pre- and post-cleaning and disinfection standard operating protocol (SOP) and after UV-C disinfection (160 sampling sites in each condition, 480 in total). Dosimeters were applied at the sites to assess the dose emitted. A total of 64.3% (103/160) of the sampling sites tested after SOP were positive, whereas only 17.5% (28/160) were positive after UV-C. According to the national hygienic standards for health-care setting, 9.3% (15/160) resulted in being non-compliant after SOP and only 1.2% (2/160) were non-compliant after UV-C disinfection. Operation theaters was the setting that resulted in being less compliant with the standard limit (≤15 colony-forming unit/24 cm2) after SOP (12%, 14/120 sampling sites) and where the UV-C treatment showed the highest effectiveness (1.6%, 2/120). The addition of UV-C disinfection to the standard cleaning and disinfection procedure had effective results in reducing hygiene failures.
Subject(s)
Keywords

Full text: Available Collection: International databases Database: MEDLINE Main subject: Robotics / Cross Infection Type of study: Experimental Studies / Randomized controlled trials Limits: Humans Language: English Year: 2023 Document Type: Article Affiliation country: Ijerph20054284

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Main subject: Robotics / Cross Infection Type of study: Experimental Studies / Randomized controlled trials Limits: Humans Language: English Year: 2023 Document Type: Article Affiliation country: Ijerph20054284