Your browser doesn't support javascript.
The impact of oxygen supply flow rates on the distribution of aerosols between the patient and the surgeon during lung intubation
International Journal of Air-Conditioning and Refrigeration ; 30(1), 2022.
Article in English | Scopus | ID: covidwho-2269146
ABSTRACT
The outbreak of COVID-19 has caused a worldwide pandemic. The widespread infection of the medical staff has caused great attention from all quarters of society. There is a particular concern when considering intubation treatment in the emergency operating room, where a significant amount of virus droplets are typically spread within the room, exposing the medical staff to a high risk of infection. Hence, there is currently a pressing need to develop an effective protection mechanism for the medical staff to prevent them from being infected during routine work. In order to understand the spread of droplets and aerosols when different oxygen supply devices are used for intubation therapy, this study uses particle image velocimetry (PIV) technology to analyze the airflow distribution between the medical staff and the patient. In the experiment, a simple version of the respirator was established to reproduce the breathing of human lungs. This model used oil to create smoke as a tracer aerosol, then a high-sensitivity camera was used to record the scattering light from this smoke (which is irradiated by the green laser sheet). Ultimately, after applying post-processing techniques, the airflow distribution is analyzed. PAO aerosol is the primary aerosol source in this experiment, and it is used to quantify the patient's breathing;the concentration of PAO aerosol was measured at three different points head, trunk, and feet. In addition, flow field visualization can effectively present the flow field distribution of the entire operating room;also, the results can be mutually verified with the PAO concentration measurement results. Aerosol concentrations were measured for six different oxygen supply devices with various tidal volumes of the artificial respirator, and the results were ranked from high to low concentrations for different oxygen supply devices and their operational oxygen supply flowrates HFNC (70 l/min) > CPAP (40 l/min) > HFNC (30 l/min) > nasal cannula (15 l/min) > NRM (15 l/min) > VAPOX (28 l/min). © 2022, The Author(s).
Keywords

Full text: Available Collection: Databases of international organizations Database: Scopus Type of study: Experimental Studies Language: English Journal: International Journal of Air-Conditioning and Refrigeration Year: 2022 Document Type: Article

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: Databases of international organizations Database: Scopus Type of study: Experimental Studies Language: English Journal: International Journal of Air-Conditioning and Refrigeration Year: 2022 Document Type: Article