Your browser doesn't support javascript.
Homogeneous circle-to-circle amplification for real-time optomagnetic detection of SARS-CoV-2 RdRp coding sequence.
Tian, Bo; Gao, Fei; Fock, Jeppe; Dufva, Martin; Hansen, Mikkel Fougt.
  • Tian B; Department of Health Technology, Technical University of Denmark, DTU Health Tech, Building 345C, DK-2800, Kongens Lyngby, Denmark. Electronic address: botia@dtu.dk.
  • Gao F; Department of Physics, Technical University of Denmark, DTU Physics, Building 307, DK-2800, Kongens Lyngby, Denmark.
  • Fock J; Blusense Diagnostics ApS, Fruebjergvej 3, DK-2100, Copenhagen, Denmark.
  • Dufva M; Department of Health Technology, Technical University of Denmark, DTU Health Tech, Building 345C, DK-2800, Kongens Lyngby, Denmark.
  • Hansen MF; Department of Health Technology, Technical University of Denmark, DTU Health Tech, Building 345C, DK-2800, Kongens Lyngby, Denmark. Electronic address: mfha@dtu.dk.
Biosens Bioelectron ; 165: 112356, 2020 Oct 01.
Article in English | MEDLINE | ID: covidwho-505616
ABSTRACT
Circle-to-circle amplification (C2CA) is a specific and precise cascade nucleic acid amplification method consisting of more than one round of padlock probe ligation and rolling circle amplification (RCA). Although C2CA provides a high amplification efficiency with a negligible increase of false-positive risk, it contains several step-by-step operation processes. We herein demonstrate a homogeneous and isothermal nucleic acid quantification strategy based on C2CA and optomagnetic analysis of magnetic nanoparticle (MNP) assembly. The proposed homogeneous circle-to-circle amplification eliminates the need for additional monomerization and ligation steps after the first round of RCA, and combines two amplification rounds in a one-pot reaction. The second round of RCA produces amplicon coils that anneal to detection probes grafted onto MNPs, resulting in MNP assembly that can be detected in real-time using an optomagnetic sensor. The proposed methodology was applied for the detection of a synthetic complementary DNA of SARS-CoV-2 (severe acute respiratory syndrome coronavirus 2, also known as 2019-nCoV) RdRp (RNA-dependent RNA polymerase) coding sequence, achieving a detection limit of 0.4 fM with a dynamic detection range of 3 orders of magnitude and a total assay time of ca. 100 min. A mathematical model was set up and validated to predict the assay performance. Moreover, the proposed method was specific to distinguish SARS-CoV and SARS-CoV-2 sequences with high similarity.
Subject(s)
Keywords

Full text: Available Collection: International databases Database: MEDLINE Main subject: Pneumonia, Viral / Biosensing Techniques / DNA, Complementary / Coronavirus Infections / Nucleic Acid Amplification Techniques / Betacoronavirus Type of study: Diagnostic study / Prognostic study Limits: Humans Language: English Journal: Biosens Bioelectron Journal subject: Biotechnology Year: 2020 Document Type: Article

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Main subject: Pneumonia, Viral / Biosensing Techniques / DNA, Complementary / Coronavirus Infections / Nucleic Acid Amplification Techniques / Betacoronavirus Type of study: Diagnostic study / Prognostic study Limits: Humans Language: English Journal: Biosens Bioelectron Journal subject: Biotechnology Year: 2020 Document Type: Article