Your browser doesn't support javascript.
Measurement of airborne particle exposure during simulated tracheal intubation using various proposed aerosol containment devices during the COVID-19 pandemic.
Simpson, J P; Wong, D N; Verco, L; Carter, R; Dzidowski, M; Chan, P Y.
  • Simpson JP; Intensive Care Services and Department of Anaesthesia and Perioperative Medicine, Eastern Health, Melbourne, Victoria, Australia.
  • Wong DN; Department of Anaesthesia and Perioperative Medicine, Eastern Health, Melbourne, Victoria, Australia.
  • Verco L; Department of Anaesthesia and Perioperative Medicine, Eastern Health, Melbourne, Victoria, Australia.
  • Carter R; Department of Anaesthesia and Perioperative Medicine, Eastern Health, Melbourne, Victoria, Australia.
  • Dzidowski M; Ascent Vision Systems, Melbourne, Victoria, Australia.
  • Chan PY; Ascent Vision Systems, Melbourne, Victoria, Australia.
Anaesthesia ; 75(12): 1587-1595, 2020 12.
Article in English | MEDLINE | ID: covidwho-608319
ABSTRACT
The COVID-19 pandemic has led to the production of novel devices intended to protect airway managers during the aerosol-generating procedure of tracheal intubation. Using an in-situ simulation model, we evaluated laryngoscopist exposure of airborne particles sized 0.3 - 5.0 microns using five aerosol containment devices (aerosol box; sealed box with and without suction; vertical drape; and horizontal drape) compared with no aerosol containment device. Nebulised saline was used as the aerosol-generating model for 300 s, at which point, the devices were removed to assess particle spread. Primary outcome was the quantity and size of airborne particles measured at the level of the laryngoscopist's head at 30, 60, 120 and 300 s, as well as 360 s (60 s after device removal). Airborne particles sizes of 0.3, 0.5, 1.0, 2.5 and 5.0 microns were quantified using an electronic airborne particle counter. Compared with no device use, the sealed intubation box with suction resulted in a decrease in 0.3, 0.5, 1.0 and 2.5 micron, but not 5.0 micron, particle exposure over all time-periods (p = 0.003 for all time periods). Compared with no device use, the aerosol box showed an increase in 1.0, 2.5 and 5.0 micron airborne particle exposure at 300 s (p = 0.002, 0.008, 0.002, respectively). Compared with no device use, neither horizontal nor vertical drapes showed any difference in any particle size exposure at any time. Finally, when the patient coughed, use of the aerosol box resulted in a marked increase in airborne particle exposure compared with other devices or no device use. In conclusion, novel devices intended to protect the laryngoscopist require objective testing to ensure they are fit for purpose and do not result in increased airborne particle exposure.
Subject(s)
Keywords

Full text: Available Collection: International databases Database: MEDLINE Main subject: Pneumonia, Viral / Infectious Disease Transmission, Patient-to-Professional / Coronavirus Infections / Inhalation Exposure / Aerosols / Particulate Matter / Airway Management / Pandemics / Intubation, Intratracheal Type of study: Cohort study / Experimental Studies / Observational study / Prognostic study Limits: Humans Language: English Journal: Anaesthesia Year: 2020 Document Type: Article Affiliation country: Anae.15188

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Main subject: Pneumonia, Viral / Infectious Disease Transmission, Patient-to-Professional / Coronavirus Infections / Inhalation Exposure / Aerosols / Particulate Matter / Airway Management / Pandemics / Intubation, Intratracheal Type of study: Cohort study / Experimental Studies / Observational study / Prognostic study Limits: Humans Language: English Journal: Anaesthesia Year: 2020 Document Type: Article Affiliation country: Anae.15188