Your browser doesn't support javascript.
A comparison of droplet and contact contamination using 3 simulated barrier techniques for COVID-19 intubation: a quality assurance study.
Rose, Peter; Veall, John; Chima, Navraj; Vowels, Elena; Chitnis, Shruti; Flexman, Alana; Tang, Raymond.
  • Rose P; Department of Anesthesiology, Pharmacology and Therapeutics, University of British Columbia, Vancouver General Hospital, Vancouver, BC peter.rose3@vch.ca.
  • Veall J; Department of Anesthesiology, Pharmacology and Therapeutics, University of British Columbia, Vancouver General Hospital, Vancouver, BC.
  • Chima N; Department of Anesthesiology, Pharmacology and Therapeutics, University of British Columbia, Vancouver General Hospital, Vancouver, BC.
  • Vowels E; Department of Anesthesiology, Pharmacology and Therapeutics, University of British Columbia, Vancouver General Hospital, Vancouver, BC.
  • Chitnis S; Department of Anesthesiology, Pharmacology and Therapeutics, University of British Columbia, Vancouver General Hospital, Vancouver, BC.
  • Flexman A; Department of Anesthesiology, Pharmacology and Therapeutics, University of British Columbia, Vancouver General Hospital, Vancouver, BC.
  • Tang R; Department of Anesthesiology, Pharmacology and Therapeutics, University of British Columbia, Vancouver General Hospital, Vancouver, BC.
CMAJ Open ; 8(3): E554-E559, 2020.
Article in English | MEDLINE | ID: covidwho-740585
ABSTRACT

BACKGROUND:

The intubation of patients with coronavirus disease 2019 (COVID-19) puts health care workers at risk of infection through aerosol, droplet and contact contamination. We evaluated the risk of droplet and contact contamination for health care workers using 3 intubation barrier techniques as part of a quality assurance study at our institution.

METHODS:

This randomized quality assurance study was completed at a tertiary academic hospital in Vancouver, British Columbia, Canada, on Apr. 4, 2020. Participants in personal protective equipment performed simulated intubations on a manikin with (a) no barrier, (b) a clear plastic sheet covering the manikin and (c) a plexiglass intubation box over the manikin, in random order. Fluorescein was ejected from inside the manikin's mouth to simulate droplet and contact spread during a standard intubation sequence. Two blinded independent assessors evaluated the location and degree of contamination on the intubator and assistant using an ultraviolet light. Contamination severity was rated in a standard fashion (0 = none; 1 = minor; 2 = major). The primary outcome was total contamination score and secondary outcomes were scores between intubator and assistant, anatomic areas contaminated and qualitative feedback on ease of intubation.

RESULTS:

Five participants completed this study. Total contamination score was different between the 3 groups for the intubator (p = 0.02) but not the assistant (p = 0.2). For the intubator, the total contamination score was higher when the sheet was used (median 29 [interquartile range (IQR) 25-34]) than when the box was used (median 17 [IQR 15-22]) or when no barrier was used (median 18 [IQR 13-21]). All 5 participants reported challenges during intubation using the sheet.

INTERPRETATION:

Use of a plastic sheet while intubating patients with COVID-19 may increase the risk of droplet and contact contamination during intubation and impede intubation. Further study should be undertaken before implementing barrier techniques in practice.
Subject(s)

Full text: Available Collection: International databases Database: MEDLINE Main subject: Quality Assurance, Health Care / Disease Transmission, Infectious / Personal Protective Equipment / COVID-19 / Intubation, Intratracheal Type of study: Diagnostic study / Experimental Studies / Observational study / Prognostic study / Qualitative research / Randomized controlled trials Limits: Adult / Female / Humans / Male / Middle aged Country/Region as subject: North America Language: English Journal: CMAJ Open Year: 2020 Document Type: Article

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Main subject: Quality Assurance, Health Care / Disease Transmission, Infectious / Personal Protective Equipment / COVID-19 / Intubation, Intratracheal Type of study: Diagnostic study / Experimental Studies / Observational study / Prognostic study / Qualitative research / Randomized controlled trials Limits: Adult / Female / Humans / Male / Middle aged Country/Region as subject: North America Language: English Journal: CMAJ Open Year: 2020 Document Type: Article