Your browser doesn't support javascript.
[Acute Neurointerventions, Covid-19 and Chest-CT: SOP and Literature Review]. / Notfällige Neurointerventionen, Covid-19 und Thorax-CT: SOP und Literaturübersicht.
Urbach, Horst; Janssen, Hendrik; Linn, Jennifer; Hoffmann, Titus; Tritt, Stephanie; Weber, Werner; Wiesmann, Martin.
  • Urbach H; Klinik für Neuroradiologie, Universitätsklinik Freiburg, Breisacher Str. 64, 79106, Freiburg, Deutschland. horst.urbach@uniklinik-freiburg.de.
  • Janssen H; Institut für Neuroradiologie, Klinikum Ingolstadt, Ingolstadt, Deutschland.
  • Linn J; Institut für Diagnostische und Interventionelle Neuroradiologie, Universitätsklinikum Dresden, Dresden, Deutschland.
  • Hoffmann T; Institut für Neuroradiologie, Universitätsmedizin Leipzig, Leipzig, Deutschland.
  • Tritt S; Institut für Radiologie und Neuroradiologie, Wiesbaden, Deutschland.
  • Weber W; Institut für Diagnostische und Interventionelle Radiologie, Neuroradiologie und Nuklearmedizin, Universitätsklinikum Knappschaftskrankenhaus Bochum, Bochum, Deutschland.
  • Wiesmann M; Klinik für Diagnostische und Interventionelle Neuroradiologie, Universitätsklinikum Aachen, Aachen, Deutschland.
Clin Neuroradiol ; 30(3): 447-452, 2020 Sep.
Article in German | MEDLINE | ID: covidwho-754693
ABSTRACT
BACKGROUND AND

PURPOSE:

To analyze standard operating procedures (SOP) of acute stroke imaging and interventions during COVID-19 pandemic with special emphasis on chest CT within a multimodal stroke protocol.

METHODS:

A questionnaire was distributed via email to members of the Professional Organization of German Neuroradiologists (Berufsverband Deutscher Neuroradiologen e.V.).

RESULTS:

Answers were received from 25 units eleven of them acquire chest CT, three in any patient and eight, when COVID-19 is suspected due to body temperature increase, patient's history or when the latter cannot be sufficiently obtained. Preliminary data indicate a high sensitivity and moderate negative predictive value.

CONCLUSION:

Different SOP reflect an uncertainty whether chest CT should be acquired as part of a multimodal stroke protocol. Accuracy of low dose chest CT cannot be determined yet. The strengths and limitations of chest CT are discussed.
Subject(s)
Keywords

Full text: Available Collection: International databases Database: MEDLINE Main subject: Pneumonia, Viral / Practice Patterns, Physicians' / Coronavirus Infections / Stroke / Lung Type of study: Observational study / Prognostic study / Randomized controlled trials / Reviews Topics: Long Covid Limits: Humans Country/Region as subject: Europa Language: German Journal: Clin Neuroradiol Journal subject: Neurology / Radiology Year: 2020 Document Type: Article

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Main subject: Pneumonia, Viral / Practice Patterns, Physicians' / Coronavirus Infections / Stroke / Lung Type of study: Observational study / Prognostic study / Randomized controlled trials / Reviews Topics: Long Covid Limits: Humans Country/Region as subject: Europa Language: German Journal: Clin Neuroradiol Journal subject: Neurology / Radiology Year: 2020 Document Type: Article