Impact of lockdown on the microbiological status of the hospital water network during COVID-19 pandemic.
De Giglio, Osvalda; Diella, Giusy; Lopuzzo, Marco; Triggiano, Francesco; Calia, Carla; Pousis, Chrysovalentinos; Fasano, Fabrizio; Caggiano, Giuseppina; Calabrese, Giuseppe; Rafaschieri, Vincenza; Carpagnano, Federica; Carlucci, Matilde; Gesualdo, Loreto; Ricci, Maria Luisa; Scaturro, Maria; Rota, Maria Cristina; Bonadonna, Lucia; Lucentini, Luca; Montagna, Maria Teresa.
  • De Giglio O; Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy. Electronic address: osvalda.degiglio@uniba.it.
  • Diella G; Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy. Electronic address: giusy.diella@uniba.it.
  • Lopuzzo M; Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy. Electronic address: marcolopuzzo@gmail.com.
  • Triggiano F; Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy. Electronic address: francesco.triggiano@uniba.it.
  • Calia C; Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy. Electronic address: carla.calia@uniba.it.
  • Pousis C; Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy. Electronic address: vpousis@gmail.com.
  • Fasano F; Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy. Electronic address: fabrizio.fasano1979@libero.it.
  • Caggiano G; Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy. Electronic address: giuseppina.caggiano@uniba.it.
  • Calabrese G; A.O.U. Policlinico di Bari, Italy. Electronic address: giuseppe.calabrese@policlinico.ba.it.
  • Rafaschieri V; A.O.U. Policlinico di Bari, Italy. Electronic address: vincenza.rafaschieri@policlinico.ba.it.
  • Carpagnano F; A.O.U. Policlinico di Bari, Italy. Electronic address: dr.fedecarpagnano@gmail.com.
  • Carlucci M; A.O.U. Policlinico di Bari, Italy. Electronic address: matilde.carlucci@policlinico.ba.it.
  • Gesualdo L; Department of Emergency and Organ Transplantation-Nephrology, Dialysis and Transplantation Unit, University of Bari Aldo Moro, Bari, 70124, Italy. Electronic address: loreto.gesualdo@uniba.it.
  • Ricci ML; Department of Infectious Diseases, Istituto Superiore di Sanità, Viale Regina Elena, 299-00161, Rome, Italy. Electronic address: marialuisa.ricci@iss.it.
  • Scaturro M; Department of Infectious Diseases, Istituto Superiore di Sanità, Viale Regina Elena, 299-00161, Rome, Italy. Electronic address: maria.scaturro@iss.it.
  • Rota MC; Department of Infectious Diseases, Istituto Superiore di Sanità, Viale Regina Elena, 299-00161, Rome, Italy. Electronic address: mariacristina.rota@iss.it.
  • Bonadonna L; Department of Environment and Health, Istituto Superiore di Sanità, Viale Regina Elena, 299-00161, Rome, Italy. Electronic address: lucia.bonadonna@iss.it.
  • Lucentini L; Department of Environment and Health, Istituto Superiore di Sanità, Viale Regina Elena, 299-00161, Rome, Italy. Electronic address: luca.lucentini@iss.it.
  • Montagna MT; Regional Reference Laboratory of Clinical and Environmental Surveillance of Legionellosis, Department of Biomedical Science and Human Oncology, University of Bari Aldo Moro, Piazza G. Cesare 11, 70124, Bari, Italy. Electronic address: mariateresa.montagna@uniba.it.
Environ Res ; 191: 110231, 2020 12.
Article in English | MEDLINE | ID: covidwho-785565
ABSTRACT
The COVID-19 pandemic started in China in early December 2019, and quickly spread around the world. The epidemic gradually started in Italy at the end of February 2020, and by May 31, 2020, 232,664 cases and 33,340 deaths were confirmed. As a result of this pandemic, the Italian Ministerial Decree issued on March 11, 2020, enforced lockdown; therefore, many social, recreational, and cultural centers remained closed for months. In Apulia (southern Italy), all non-urgent hospital activities were suspended, and some wards were closed, with a consequent reduction in the use of the water network and the formation of stagnant water. This situation could enhance the risk of exposure of people to waterborne diseases, including legionellosis. The purpose of this study was to monitor the microbiological quality of the water network (coliforms, E. coli, Enterococci, P. aeruginosa, and Legionella) in three wards (A, B and C) of a large COVID-19 regional hospital, closed for three months due to the COVID-19 emergency. Our study revealed that all three wards' water network showed higher contamination by Legionella pneumophila sg 1 and sg 6 at T1 (after lockdown) compared to the period before the lockdown (T0). In particular, ward A at T1 showed a median value = 5600 CFU/L (range 0-91,000 CFU/L) vs T0, median value = 75 CFU/L (range 0-5000 CFU/L) (p-value = 0.014); ward B at T1 showed a median value = 200 CFU/L (range 0-4200 CFU/L) vs T0, median value = 0 CFU/L (range 0-300 CFU/L) (p-value = 0.016) and ward C at T1 showed a median value = 175 CFU/L (range 0-22,000 CFU/L) vs T0, median value = 0 CFU/L (range 0-340 CFU/L) (p-value < 0.001). In addition, a statistically significant difference was detected in ward B between the number of positive water samples at T0 vs T1 for L. pneumophila sg 1 and sg 6 (24% vs 80% p-value < 0.001) and for coliforms (0% vs 64% p-value < 0.001). Moreover, a median value of coliform load resulted 3 CFU/100 ml (range 0-14 CFU/100 ml) at T1, showing a statistically significant increase versus T0 (0 CFU/100 ml) (p-value < 0.001). Our results highlight the need to implement a water safety plan that includes staff training and a more rigorous environmental microbiological surveillance in all hospitals before occupying a closed ward for a longer than one week, according to national and international guidelines.
Subject(s)
Keywords

Full text: Available Collection: International databases Database: MEDLINE Main subject: Pneumonia, Viral / Legionella pneumophila / Coronavirus Infections / Pandemics Type of study: Experimental Studies / Observational study / Prognostic study Limits: Humans Country/Region as subject: Asia / Europa Language: English Journal: Environ Res Year: 2020 Document Type: Article

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Main subject: Pneumonia, Viral / Legionella pneumophila / Coronavirus Infections / Pandemics Type of study: Experimental Studies / Observational study / Prognostic study Limits: Humans Country/Region as subject: Asia / Europa Language: English Journal: Environ Res Year: 2020 Document Type: Article