Your browser doesn't support javascript.
Remote Fingerstick Blood Collection for Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) Antibody Testing.
Garcia-Beltran, Wilfredo F; Miller, Tyler E; Kirkpatrick, Grace; Nixon, Andrea; Astudillo, Michael G; Yang, Diane; Mahanta, Lisa M; Murali, Mandakolathur; Dighe, Anand S; Lennerz, Jochen; Thierauf, Julia; Naranbhai, Vivek; Iafrate, A John.
  • Garcia-Beltran WF; From the Departments of Pathology (Garcia-Beltran, Miller, Kirkpatrick, Nixon, Astudillo, Yang, Murali, Dighe, Lennerz, Thierauf, Iafrate), Massachusetts General Hospital, Boston.
  • Miller TE; Garcia-Beltran and Miller contributed equally to this work.
  • Kirkpatrick G; From the Departments of Pathology (Garcia-Beltran, Miller, Kirkpatrick, Nixon, Astudillo, Yang, Murali, Dighe, Lennerz, Thierauf, Iafrate), Massachusetts General Hospital, Boston.
  • Nixon A; Garcia-Beltran and Miller contributed equally to this work.
  • Astudillo MG; From the Departments of Pathology (Garcia-Beltran, Miller, Kirkpatrick, Nixon, Astudillo, Yang, Murali, Dighe, Lennerz, Thierauf, Iafrate), Massachusetts General Hospital, Boston.
  • Yang D; From the Departments of Pathology (Garcia-Beltran, Miller, Kirkpatrick, Nixon, Astudillo, Yang, Murali, Dighe, Lennerz, Thierauf, Iafrate), Massachusetts General Hospital, Boston.
  • Mahanta LM; From the Departments of Pathology (Garcia-Beltran, Miller, Kirkpatrick, Nixon, Astudillo, Yang, Murali, Dighe, Lennerz, Thierauf, Iafrate), Massachusetts General Hospital, Boston.
  • Murali M; From the Departments of Pathology (Garcia-Beltran, Miller, Kirkpatrick, Nixon, Astudillo, Yang, Murali, Dighe, Lennerz, Thierauf, Iafrate), Massachusetts General Hospital, Boston.
  • Dighe AS; Mass General Brigham Biobank, Boston, Massachusetts (Mahanta).
  • Lennerz J; From the Departments of Pathology (Garcia-Beltran, Miller, Kirkpatrick, Nixon, Astudillo, Yang, Murali, Dighe, Lennerz, Thierauf, Iafrate), Massachusetts General Hospital, Boston.
  • Thierauf J; Medicine (Murali, Naranbhai), Massachusetts General Hospital, Boston.
  • Naranbhai V; From the Departments of Pathology (Garcia-Beltran, Miller, Kirkpatrick, Nixon, Astudillo, Yang, Murali, Dighe, Lennerz, Thierauf, Iafrate), Massachusetts General Hospital, Boston.
  • Iafrate AJ; From the Departments of Pathology (Garcia-Beltran, Miller, Kirkpatrick, Nixon, Astudillo, Yang, Murali, Dighe, Lennerz, Thierauf, Iafrate), Massachusetts General Hospital, Boston.
Arch Pathol Lab Med ; 145(4): 415-418, 2021 04 01.
Article in English | MEDLINE | ID: covidwho-1150896
ABSTRACT
The rapid worldwide spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection has propelled the rapid development of serologic tests that can detect anti-SARS-CoV-2 antibodies. These have been used for studying the prevalence and spread of infection in different populations, and helping establish a recent diagnosis of coronavirus disease 2019 (COVID-19), and will likely be used to confirm humoral immunity after infection or vaccination. However, nearly all lab-based high-throughput SARS-CoV-2 serologic assays require a serum sample from venous blood draw, limiting their applications and scalability. Here, we present a method that enables large-scale SARS-CoV-2 serologic studies by combining self or office collection of fingerprick blood with a volumetric absorptive microsampling device (Mitra, Neoteryx LLC) with a high-throughput electrochemiluminescence-based SARS-CoV-2 total antibody assay (Roche Elecsys, Roche Diagnostics Inc) that is emergency use authorization approved for use on serum samples and widely used by clinical laboratories around the world. We found that the Roche Elecsys assay has a high dynamic range that allows for accurate detection of SARS-CoV-2 antibodies in serum samples diluted 120 as well as contrived dried blood extracts. Extracts of dried blood from Mitra devices acquired in a community seroprevalence study showed near identical sensitivity and specificity in detection of SARS-CoV-2 antibodies compared with neat sera using predefined thresholds for each specimen type. Overall, this study affirms the use of Mitra dried blood collection device with the Roche Elecsys SARS-CoV-2 total antibody assay for remote or at-home testing as well as large-scale community seroprevalence studies.
Subject(s)

Full text: Available Collection: International databases Database: MEDLINE Main subject: COVID-19 Serological Testing / SARS-CoV-2 / COVID-19 / Antibodies, Viral Type of study: Diagnostic study / Observational study / Prognostic study Topics: Vaccines Limits: Humans Language: English Journal: Arch Pathol Lab Med Year: 2021 Document Type: Article

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Main subject: COVID-19 Serological Testing / SARS-CoV-2 / COVID-19 / Antibodies, Viral Type of study: Diagnostic study / Observational study / Prognostic study Topics: Vaccines Limits: Humans Language: English Journal: Arch Pathol Lab Med Year: 2021 Document Type: Article