Your browser doesn't support javascript.
Risk assessment of airborne transmission of COVID-19 by asymptomatic individuals under different practical settings.
Shao, Siyao; Zhou, Dezhi; He, Ruichen; Li, Jiaqi; Zou, Shufan; Mallery, Kevin; Kumar, Santosh; Yang, Suo; Hong, Jiarong.
  • Shao S; Department of Mechanical Engineering, 111 Church ST SE, University of Minnesota, Minneapolis, MN, 55414, USA.
  • Zhou D; Saint Anthony Falls Laboratory, 2 3rd AVE SE, University of Minnesota, Minneapolis, MN, 55414, USA.
  • He R; Department of Mechanical Engineering, 111 Church ST SE, University of Minnesota, Minneapolis, MN, 55414, USA.
  • Li J; Department of Mechanical Engineering, 111 Church ST SE, University of Minnesota, Minneapolis, MN, 55414, USA.
  • Zou S; Saint Anthony Falls Laboratory, 2 3rd AVE SE, University of Minnesota, Minneapolis, MN, 55414, USA.
  • Mallery K; Department of Mechanical Engineering, 111 Church ST SE, University of Minnesota, Minneapolis, MN, 55414, USA.
  • Kumar S; Saint Anthony Falls Laboratory, 2 3rd AVE SE, University of Minnesota, Minneapolis, MN, 55414, USA.
  • Yang S; Department of Mechanical Engineering, 111 Church ST SE, University of Minnesota, Minneapolis, MN, 55414, USA.
  • Hong J; Department of Mechanical Engineering, 111 Church ST SE, University of Minnesota, Minneapolis, MN, 55414, USA.
J Aerosol Sci ; 151: 105661, 2021 Jan.
Article in English | MEDLINE | ID: covidwho-997082
Preprint
This scientific journal article is probably based on a previously available preprint. It has been identified through a machine matching algorithm, human confirmation is still pending.
See preprint
ABSTRACT
The lack of quantitative risk assessment of airborne transmission of COVID-19 under practical settings leads to large uncertainties and inconsistencies in our preventive measures. Combining in situ measurements and computational fluid dynamics simulations, we quantify the exhaled particles from normal respiratory behaviors and their transport under elevator, small classroom, and supermarket settings to evaluate the risk of inhaling potentially virus-containing particles. Our results show that the design of ventilation is critical for reducing the risk of particle encounters. Inappropriate design can significantly limit the efficiency of particle removal, create local hot spots with orders of magnitude higher risks, and enhance particle deposition causing surface contamination. Additionally, our measurements reveal the presence of a substantial fraction of faceted particles from normal breathing and its strong correlation with breathing depth.
Keywords

Full text: Available Collection: International databases Database: MEDLINE Type of study: Experimental Studies / Prognostic study Language: English Journal: J Aerosol Sci Year: 2021 Document Type: Article Affiliation country: J.jaerosci.2020.105661

Similar

MEDLINE

...
LILACS

LIS