Your browser doesn't support javascript.
Evaluation of the QIAstat-Dx Respiratory SARS-CoV-2 Panel, the First Rapid Multiplex PCR Commercial Assay for SARS-CoV-2 Detection.
Visseaux, Benoit; Le Hingrat, Quentin; Collin, Gilles; Bouzid, Donia; Lebourgeois, Samuel; Le Pluart, Diane; Deconinck, Laurène; Lescure, François-Xavier; Lucet, Jean-Christophe; Bouadma, Lila; Timsit, Jean-François; Descamps, Diane; Yazdanpanah, Yazdan; Casalino, Enrique; Houhou-Fidouh, Nadhira.
  • Visseaux B; Université de Paris, Assistance Publique - Hôpitaux de Paris, Service de Virologie, Hôpital Bichat, Paris, France benoit.visseaux@aphp.fr.
  • Le Hingrat Q; UMR 1137-IAME, Decision Sciences in Infectious Diseases Control and Care (DeSCID), INSERM, Université de Paris, Paris, France.
  • Collin G; Université de Paris, Assistance Publique - Hôpitaux de Paris, Service de Virologie, Hôpital Bichat, Paris, France.
  • Bouzid D; UMR 1137-IAME, Decision Sciences in Infectious Diseases Control and Care (DeSCID), INSERM, Université de Paris, Paris, France.
  • Lebourgeois S; Université de Paris, Assistance Publique - Hôpitaux de Paris, Service de Virologie, Hôpital Bichat, Paris, France.
  • Le Pluart D; UMR 1137-IAME, Decision Sciences in Infectious Diseases Control and Care (DeSCID), INSERM, Université de Paris, Paris, France.
  • Deconinck L; UMR 1137-IAME, Decision Sciences in Infectious Diseases Control and Care (DeSCID), INSERM, Université de Paris, Paris, France.
  • Lescure FX; Université de Paris, Assistance Publique - Hôpitaux de Paris, Service d'Accueil des Urgences, Hôpital Bichat, Paris, France.
  • Lucet JC; Université de Paris, Assistance Publique - Hôpitaux de Paris, Service de Virologie, Hôpital Bichat, Paris, France.
  • Bouadma L; UMR 1137-IAME, Decision Sciences in Infectious Diseases Control and Care (DeSCID), INSERM, Université de Paris, Paris, France.
  • Timsit JF; Université de Paris, Service de Maladies Infectieuses et Tropicales, Hôpital Bichat Claude Bernard, Assistance Publique - Hôpitaux de Paris, Paris, France.
  • Descamps D; Université de Paris, Service de Maladies Infectieuses et Tropicales, Hôpital Bichat Claude Bernard, Assistance Publique - Hôpitaux de Paris, Paris, France.
  • Yazdanpanah Y; UMR 1137-IAME, Decision Sciences in Infectious Diseases Control and Care (DeSCID), INSERM, Université de Paris, Paris, France.
  • Casalino E; Université de Paris, Service de Maladies Infectieuses et Tropicales, Hôpital Bichat Claude Bernard, Assistance Publique - Hôpitaux de Paris, Paris, France.
  • Houhou-Fidouh N; UMR 1137-IAME, Decision Sciences in Infectious Diseases Control and Care (DeSCID), INSERM, Université de Paris, Paris, France.
J Clin Microbiol ; 58(8)2020 Jul 23.
Article in English | MEDLINE | ID: covidwho-999192
ABSTRACT
In the race to contain severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), efficient detection and triage of infected patients must rely on rapid and reliable testing. In this work, we performed the first evaluation of the QIAstat-Dx respiratory SARS-CoV-2 panel (QIAstat-SARS) for SARS-CoV-2 detection. This assay is the first rapid multiplex PCR (mPCR) assay, including SARS-CoV-2 detection, and is fully compatible with a non-PCR-trained laboratory or point-of-care (PoC) testing. This evaluation was performed using 69 primary clinical samples (66 nasopharyngeal swabs [NPS], 1 bronchoalveolar lavage fluid sample [BAL], 1 tracheal aspirate sample, and 1 bronchial aspirate sample) comparing SARS-CoV-2 detection with the currently WHO-recommended reverse transcription-PCR (RT-PCR) (WHO-RT-PCR) workflow. Additionally, a comparative limit of detection (LoD) assessment was performed for QIAstat-SARS and WHO-RT-PCR using a quantified clinical sample. Compatibility of sample pretreatment for viral neutralization or viscous samples with the QIAstat-SARS system were also tested. The QIAstat-Dx respiratory SARS-CoV-2 panel demonstrated a sensitivity comparable to that of the WHO-recommended assay with a limit of detection at 1,000 copies/ml. The overall percent agreement between QIAstat-Dx SARS and WHO-RT-PCR on 69 clinical samples was 97% with a sensitivity of 100% (40/40) and specificity at 93% (27/29). No cross-reaction was encountered for any other respiratory viruses or bacteria included in the panel. The QIAstat-SARS rapid multiplex PCR panel provides a highly sensitive, robust, and accurate assay for rapid detection of SARS-CoV-2. This assay allows rapid decisions even in non-PCR-trained laboratory or point-of-care testing, allowing innovative organization.
Subject(s)
Keywords

Full text: Available Collection: International databases Database: MEDLINE Main subject: Pneumonia, Viral / Coronavirus Infections / Clinical Laboratory Techniques / Multiplex Polymerase Chain Reaction / Betacoronavirus Type of study: Diagnostic study / Experimental Studies / Prognostic study / Randomized controlled trials Limits: Humans Language: English Year: 2020 Document Type: Article Affiliation country: JCM.00630-20

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Collection: International databases Database: MEDLINE Main subject: Pneumonia, Viral / Coronavirus Infections / Clinical Laboratory Techniques / Multiplex Polymerase Chain Reaction / Betacoronavirus Type of study: Diagnostic study / Experimental Studies / Prognostic study / Randomized controlled trials Limits: Humans Language: English Year: 2020 Document Type: Article Affiliation country: JCM.00630-20