This article is a Preprint
Preprints are preliminary research reports that have not been certified by peer review. They should not be relied on to guide clinical practice or health-related behavior and should not be reported in news media as established information.
Preprints posted online allow authors to receive rapid feedback and the entire scientific community can appraise the work for themselves and respond appropriately. Those comments are posted alongside the preprints for anyone to read them and serve as a post publication assessment.
Evaluation of pooling of samples for testing SARS-COV- 2 for mass screening of COVID-19 (preprint)
medrxiv; 2021.
Preprint
in English
| medRxiv | ID: ppzbmed-10.1101.2021.03.15.21253567
ABSTRACT
BackgroundThe current pandemic of SARS- COV- 2 virus, widely known as COVID-19 has affected millions of people around the world. The World Health Organization (WHO) has recommended vigorous testing to differentiate SARS-CoV-2 from other respiratory infections to aid in guiding appropriate care and management. Situations like this have demanded robust testing strategies and pooled testing of samples for SARS- COV- 2 virus has provided the solution to mass screening of people. The pooled testing strategy can be very effective in testing with limited resources, yet it comes with its own limitations. These limitations need critical consideration when it comes to testing of highly infectious disease like COVID -19. MethodsThe study evaluated the pooled testing of nasopharyngeal swabs for SARS- COV- 2 by comparing sensitivity of individual sample testing with 4 and 8 pool sample testing. Median cycle threshold (Ct) values were compared. The precision of pooled testing was assessed by doing an inter and intra assay of pooled samples. Coefficient of variance was calculated for inter and intra assay variability. ResultsThe sensitivity becomes considerably low when the samples are pooled, there is a higher percentage of false negatives with higher pool size and when the patient viral load is low or weak positive samples. High variability was seen in the intra and inter assay, especially in weak positive samples and larger pool size. ConclusionAs COVID - 19 numbers are still high and testing capacity needs to be high, we have to meticulously evaluate the testing strategy for each country depending on its testing capacity, infrastructure, economic strength, and need to make a serious call on cost effective strategy of resource saving and risk/ cost of missing positive patients.
Full text:
Available
Collection:
Preprints
Database:
medRxiv
Main subject:
COVID-19
Language:
English
Year:
2021
Document Type:
Preprint
Similar
MEDLINE
...
LILACS
LIS