This article is a Preprint
Preprints are preliminary research reports that have not been certified by peer review. They should not be relied on to guide clinical practice or health-related behavior and should not be reported in news media as established information.
Preprints posted online allow authors to receive rapid feedback and the entire scientific community can appraise the work for themselves and respond appropriately. Those comments are posted alongside the preprints for anyone to read them and serve as a post publication assessment.
Nebulized recombinant tissue plasminogen activator (rt-PA) for acute COVID-19-induced severe respiratory failure: an exploratory proof of concept trial (preprint)
preprints.org; 2023.
Preprint
in English
| PREPRINT-PREPRINTS.ORG | ID: ppzbmed-10.20944.preprints202306.1455.v1
ABSTRACT
Nebulized thrombolysis offers locally targeted therapy with potentially lower bleeding risk than systemic administration for coronavirus disease 2019 (COVID-19) respiratory failure. In a proof-of-concept safety study, adult patients with COVID-19-induced respiratory failure and a <300mmHg PaO2/FiO2 (P/F) ratio, requiring invasive mechanical ventilation (IMV) or non-invasive respiratory support (NIRS) received nebulized rt-PA in two cohorts (C1 and C2), alongside standard of care during the first two UK COVID-19 waves. Matched historical controls (MHC; n=18) were used in C1. Safety co-primary endpoints were treatment-related bleeds and fibrinogen reduction to <1.0–1.5 g/L. A dose escalation strategy for improved efficacy with the least safety concerns was determined in C1 for use in C2; patients were stratified by ventilation type to receive 40–60 mg rt-PA per day for ≤14 days. Nine patients in C1 (IMV, 6/9; NIRS, 3/9) and 26 in C2 (IMV, 12/26; NIRS, 14/26) received nebulized rt-PA for a mean (SD) of 6.7 (4.6) and 9.1(4.6) days, respectively. Four bleeding events (one severe and three mild) in three patients were considered treatment-related. No significant fibrinogen reductions were reported. Greater improvement in mean P/F ratio from baseline to end of study was observed in C1 compared with MHC [C1; 154 to 299 vs MHC; 154 to 212). In C2, there was no difference in the baseline P/F ratio of NIRS and IMV patients. However, a larger improvement in P/F ratio was observed in NIRS patients [NIRS; 126 to 240 vs IMV; 120 to 188) and they required fewer treatment days (NIRS; 7.86 vs IMV; 10.5). Nebulized rt-PA appears to be well-tolerated, showing a trend of improved oxygenation and faster recovery in patients with acute COVID-19-induced respiratory failure requiring respiratory support; this effect was more pronounced in the NIRS group. Further investigation is required to study the potential of this novel treatment approach.
Full text:
Available
Collection:
Preprints
Database:
PREPRINT-PREPRINTS.ORG
Main subject:
Respiratory Insufficiency
/
COVID-19
/
Hemorrhage
/
Neoplasm Invasiveness
Language:
English
Year:
2023
Document Type:
Preprint
Similar
MEDLINE
...
LILACS
LIS