Your browser doesn't support javascript.

Biblioteca Virtual en Salud

Hipertensión

Home > Búsqueda > ()
XML
Imprimir Exportar

Formato de exportación:

Exportar

Email
Adicionar mas contactos
| |

A straightforward one-step strategy for SARS-CoV-2 diagnosis and screening of variants of concern: a multicentre study

Fontana-Maurell, Marcela; Motta, Fernando do Couto; Arruda, Monica Barcellos; Cardoso, Pedro; Ribeiro, Marisa; Andrade, Elisabete; Godoy, Daniela T; Costa, Elaine; Rocha, Daniele; Siqueira, Marilda Agudo MT; Brindeiro, Rodrigo; Alvarez, Patrícia.
Mem. Inst. Oswaldo Cruz ; 118: e220202, 2023. tab, graf
Artículo en Inglés | LILACS-Express | ID: biblio-1422150
BACKGROUND The prevalence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants of concern (VOCs) has changed unevenly over time around the world. Although whole genome sequencing is the gold standard for virus characterisation, the discovery of alpha VOC causing spike gene target failure (SGTF) result, when tested using an reverse transcription real-time polymerase chain reaction (RT-qPCR) assay, has provided a simple tool for tracking the frequencies of variants. OBJECTIVES The aim of this study was to investigate if a multiplex RT-qPCR assay (BioM 4Plex VOC) could be used to detect SARS-CoV-2 and to perform a VOC screening test in a single reaction tube. Here, we present the multicentre study evaluating this assay. METHODS Twelve laboratories have participated in the multicentre study. The BioM 4Plex VOC was distributed to them with detailed instructions of how to perform the test. They were asked to test the BioM 4Plex VOC in parallel with their routine Commercial SARS-CoV-2 diagnostic assay. Additionally, they were requested to select SARS-CoV-2-positive samples with genome sequenced and lineage definition according to PANGO lineage classification. FINDINGS The BioM 4Plex VOC and commercial RT-PCR assay are equally effective in detecting SARS-CoV-2. Results revealed a specificity of 96.5-100% [95% confidence interval (CI)], a sensitivity of 99.8-100% (95% CI), and an accuracy of 99.8-100% (95% CI). A 99% concordance rate was found between results from the BioM 4Plex VOC and that from available genome sequencing data. MAIN CONCLUSIONS The BioM 4Plex VOC provides an effective solution to detect SARS-CoV-2 infections and screening for VOCs in a single reaction. It is a straightforward method to help us monitor the frequency and distribution of VOCs and develop strategies to better cope with the pandemics.
Biblioteca responsable: BR1.1