Clinical study of different composite resin systems in Class I cavities (an 18-month randomized clinical trial) / Estudo clínico de diferentes sistemas de resina composta em cavidades de Classe I (um ensaio clínico randomizado de 18 meses)

Ibrahim, Hend Ali; Abdalla, Ali Ibrahim; El-Sayed, Hussein Yehia.
Braz. dent. sci ; 26(3): 1-13, 2023. ilus, tab
Artículo en Inglés | LILACS, BBO - odontología (Brasil) | ID: biblio-1444656

Objective:

this double-blind randomized clinical trial evaluate the clinical performance of Thermo-Viscous Bulk Fill composite, Self-Adhesive Flowable composite, and Filtek Bulk Fill Composites restorations in Class I cavities over a period of 18 months. Material and

Methods:

twenty individuals between the ages of 30 and 45 participated in this research. Each patient should have at least three occlusal Class I carious lesions on their molars. They were dispersed at random, with n=20 teeth representing each tested material. Group I (Futurabond M+ and VisCalor Bulk Fill which heated in a viscolar dispenser at 68 °C for 30s and placed in a 4 mm thickness), Group II (Fusio Liquid Dentin self-adhesive composite which put in a thin layer (1mm increment)), and Group III (Single Bond Universal and Filtek Bulk Fill Posterior composite which applied in 4 mm thickness without heating). Using (USPHS) criteria, all restorations were assessed clinically at baseline, 6 months, 12 months, and 18 months. Using an inverse replica, the marginal seal of the investigated restorations was further evaluated under SEM. Statistical analysis was performed with Chi-square test for all USPH parameters.

Results:

the three tested groups recorded a one hundred percent retention rate after 18 months follow up period. Concerning marginal adaptation, marginal discoloration, anatomical form, surface texture, and color matching, there was a significant difference (p˂0.05) between the three tested groups after 12 & 18 months. After 12 & 18 months, SEM analysis of the marginal seal revealed a statistically significant difference between the three groups.

Conclusion:

Bulk fill resin composite restorations showed satisfactory acceptable clinical performance after 18 months of clinical service compared to self-adhesive flowable composites, and Viscalor Bulk Fill composite demonstrated excellent results with considerable changes in marginal integrity as a consequence of thermal viscous technology and increased adaptability of restorations toward cavity walls and margins (AU)