Reparación de las lesiones crónicas del manguito rotador mediante diferentes compuestos / Repair of rotator cuff injuries using different composites
Lopiz, Y; Arvinius, C; García-Fernández, C; Rodriguez-Bobada, MC; González-López, P; Civantos, A; Marco, F.
Rev. Esp. Cir. Ortop. Traumatol. (Ed. Impr.)
; 61(1): 51-62, ene.-feb. 2017. tab, ilus
Artículo
en Español
| IBECS (España) | ID: ibc-159401
Objetivo. La reparación del manguito rotador se acompaña de una elevada tasa de rerrotura. Nuestro objetivo es determinar si el empleo de rhBMP-2 vehiculizada en un transportador híbrido mejora el proceso de reparación en lesiones crónicas del manguito. Material y métodos. Estudio experimental en 62 ratas. A las 4 semanas de la lesión se llevó a cabo una sutura transósea y la asignación aleatoria a uno de los 5 grupos de estudio 1) grupo control solo sutura; 2) grupo doble-control se aplicó además un transportador de alginato-quitina; 3) grupo control-alginato se añadió rhBMP-2 al alginato; 4) grupo control-quitina se añadió rhBMP-2 a la quitina, y 5) grupo doble-muestra se añadió rhBMP-2 a ambos componentes. A los 4 meses se evaluaron los resultados mediante estudios biomecánicos e histológicos. Resultados. En todos los casos se observó una brecha osteotendinosa macroscópicamente a las 4 semanas. La tasa de rerrotura fue del 7,5%, ocurriendo el 20% de ellas en el grupo control-alginato. En la evaluación histológica los mejores resultados se obtuvieron en el grupo doble muestra 4,5 (3,3-5). La carga máxima soportada fue mayor en el grupo doble muestra 62,9N (59,8-69,4) presentando además una menor rigidez 12,7 (9,7-15,9). Conclusiones. El empleo de la rhBMP-2 vehiculizada en un transportador híbrido de alginato-quitina parece mejorar las características histológicas de la reparación e incrementar las propiedades biomecánicas del tendón en el contexto de una lesión crónica del manguito rotador (AU)
Aim. Rotator cuff repairs have shown a high level of re-ruptures. It is hypothesised that the use of rhBMP-2 in a carrier could improve the biomechanical and histological properties of the repair. Material and methods. Controlled experimental study conducted on 40 rats with section and repair of the supraspinatus tendon and randomisation to one of five groups Group 1 (control) only suture; Group 2 (double control), suture and alginate-chitin carrier; Group 3 (alginate-control), the rhBMP-2 was added to the alginate; Group 4 (chitin-control) application of the rhBMP-2 to the chitin, and Group 5 (double sample) The two components of the carrier (alginate and chitin) have rhBMP-2. A biomechanical and histological analysis was performed at 4 weeks. Results. A gap was observed in all cases 4 weeks after supraspinatus detachment. The re-rupture rate was 7.5%, with 20% of them in the control-alginate Group. Histologically the best results were obtained in the double sample group 4.5 (3.3-5.0). Double sample were also able to support higher loads to failure 62.9N (59.8 to 69.4) with lower rigidity 12.7 (9.7 to 15.9). Conclusions. The use of alginate-chitin carrier with rhBMP-2 improves the biomechanical and histological properties of the repair site in a chronic rotator cuff tear (AU)
Asunto(s)
Animales Masculino Ratas Manguito de los Rotadores/anomalías Manguito de los Rotadores/cirugía Materiales Biocompatibles/uso terapéutico Ingeniería de Tejidos/instrumentación Ingeniería de Tejidos/métodos Modelos Animales Traumatismos de los Tendones/cirugía Traumatismos de los Tendones/veterinaria Ingeniería de Tejidos/normas Ingeniería de Tejidos/tendencias Ingeniería de Tejidos Procedimientos Ortopédicos/métodos Procedimientos Ortopédicos/veterinaria Manguito de los Rotadores/lesiones Suturas Suturas/veterinaria
Biblioteca responsable:
ES1.1
Ubicación: BNCS
powered by iAHx-2.18-89
Biblioteca Virtual en Salud